98%
921
2 minutes
20
Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images ( < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 See also the editorial by Sandfort and Bluemke in this issue.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/radiol.211780 | DOI Listing |
J Neurol
September 2025
Department of Neurology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China.
Objective: To evaluate the clinical efficacy of tocilizumab, a interleukin-6 (IL-6) receptor blocker, for the treatment of acute necrotizing encephalopathy (ANE).
Methods: PubMed, Cochrane Library, Embase, and Web of Science were searched for systematic review based on PRISMA guidelines. ANE patients treated with and without tocilizumab were included.
Nihon Hoshasen Gijutsu Gakkai Zasshi
September 2025
Division of Neonatology, Maternal and Perinatal Center, Toyama University Hospital.
Purpose: This study aimed to evaluate whether low-dose CT imaging using an Sn filter can provide image quality sufficient for the differential diagnosis of cranial deformities in infants while maintaining an effective dose comparable to that of conventional radiography.
Methods: We calculated the effective dose for both head X-ray imaging and low-dose CT with an Sn filter. Phantom images acquired using a CT scanner equipped with an Sn filter were evaluated for bone suture visibility at various conditions (from 10 mAs to 50 mAs, every 10 mAs) using a 4-point visual grading scale.
Pestic Biochem Physiol
November 2025
State Key Laboratory of Agricultural and Forestry Biosecurity & Key Lab of Biopesticide and Chemical Biology, Ministry of Education, College of Plant Protection, Fujian Agriculture and Forestry University, Fuzhou 350002, PR China. Electronic address:
Rice bacterial leaf streak (BLS) caused by Xanthomonas oryzae pv. oryzicola (Xoc) significantly reduces rice yield and quality. Traditional chemical control methods often have limited efficacy and raise environmental concerns, highlighting the need for safer and more effective alternatives.
View Article and Find Full Text PDFJ Microbiol Methods
September 2025
French Armed Forces Medical Directorate, Veterinary Quality Unit, Paris, France.
Foodborne diseases are caused by various pathogens and generally present with similar symptoms, mainly digestive disorders. Adopting a syndromic approach is therefore important when investigating foodborne disease outbreaks. This involves using multiplex PCR-based methods to test stool and food samples.
View Article and Find Full Text PDFMicrobes Infect
September 2025
Institute of Medical Microbiology, University of Zurich, Zurich, Switzerland; ESCMID study group on Molecular Diagnostics and Genomics. Electronic address:
Rapid advancements in artificial intelligence (AI) and machine learning (ML) offer significant potential to transform medical microbiology diagnostics, improving pathogen identification, antimicrobial susceptibility prediction and outbreak detection. To address these opportunities and challenges, the ESCMID workshop, "Artificial Intelligence and Machine Learning in Medical Microbiology Diagnostics", was held in Zurich, Switzerland, from June 2-5, 2025. The course featured expert lectures, practical sessions and panel discussions covering foundational ML concepts and deep learning architectures, data interoperability, quality control processes, model development and validation strategies.
View Article and Find Full Text PDF