Article Abstract

This study assessed the image quality and diagnostic accuracy in determining disease activity of the terminal ileum of the reduced-dose computed tomography enterography using model-based iterative reconstruction in pediatric patients with Crohn's disease (CD). Eighteen patients were prospectively enrolled and allocated to the standard-dose (SD) and reduced-dose (RD) computed tomography enterography (CTE) groups (n = 9 per group). Image quality, reader confidence in interpreting bowel findings, accuracy in determining active CD in the terminal ileum, and radiation dose were evaluated. Objective image quality did not show intergroup differences, except for image sharpness. Although reader confidence in detecting mural stratification, ulcer, and perienteric fat stranding of the RD-CTE were inferior to SD-CTE, RD-CTE correctly diagnosed active disease in all patients. The mean values of radiation dose metrics (SD-CTE vs. RD-CTE) were 4.3 versus 0.74 mGy, 6.1 versus 1.1 mGy, 211.9 versus 34.5 mGy∙cm, and 4.4 versus 0.7 mSv mGy∙cm for CTDI, size-specific dose estimation, dose-length product, and effective dose, respectively. RD-CTE showed comparable diagnostic accuracy to SD-CTE in determining active disease of the terminal ileum in pediatric CD patients. However, image quality and reader confidence in detecting ulcer and perienteric fat stranding was compromised.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8828853PMC
http://dx.doi.org/10.1038/s41598-022-06246-zDOI Listing

Publication Analysis

Top Keywords

image quality
20
diagnostic accuracy
12
reduced-dose computed
12
computed tomography
12
tomography enterography
12
terminal ileum
12
reader confidence
12
quality diagnostic
8
enterography model-based
8
model-based iterative
8

Similar Publications

Purpose: In children with Langerhans Cell Histiocytosis (LCH), FDG-PET/CT is used for staging and response assessment. Whole-body MRI (WB-MRI) can serve as an ionizing radiation-free alternative for repeated whole-body imaging. The aim of this study was to compare WB-MRI with FDG-PET/CT for staging and response assessment in pediatric LCH.

View Article and Find Full Text PDF

Importance And Objective: Voice changes during menopause affect patients' communication and quality of life. This narrative review aims to provide a comprehensive exploration of voice changes during menopause. It presents objective and subjective/symptomatic changes as well as treatment options for this population.

View Article and Find Full Text PDF

Fetal 4D Flow CMR for Advanced Diagnostics of Congenital Heart Disease: A Prospective Cohort Study.

Eur Heart J Cardiovasc Imaging

September 2025

Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.

Aims: Fetal circulation undergoes complex changes in congenital heart disease (CHD) that are challenging to assess with fetal echocardiography. This study aimed to assess clinical feasibility and diagnostic value of 4D flow cardiac magnetic resonance (CMR) in fetal CHD.

Methods And Results: Pregnant women in advanced third trimester pregnancy with fetal CHD were prospectively recruited for fetal CMR between 08/2021 and 11/2024.

View Article and Find Full Text PDF

PurposeTo introduce, describe and validate a novel, 3D-printed portable slit lamp system integrated with a macro lens-equipped smartphone, providing clinicians with a quick, easy, and effective method for obtaining high-quality clinical images.Materials and MethodsA 3D-printed portable slit lamp was developed, comprising a warm white LED light pen housed in a custom case with a biconvex lens focusing light through a 0.4 mm slit.

View Article and Find Full Text PDF

Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality.

View Article and Find Full Text PDF