Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objective: To compare single and triplicate applanation tonometry values across previous intraocular pressure (IOP) studies in dogs.
Animals: 116 ophthalmologically normal dogs.
Procedures: Triplicate IOP readings (n = 1432) from studies evaluating effect of anesthetic protocols were analyzed to estimate a range of probable differences between averaged triplicate and first, averaged and lowest, and first and lowest IOPs. The decrease in variability with triplicate measurements and the magnitude of effects on statistical power were quantified.
Results: The 2.5th to 97.5th interpercentile range for differences of averaged triplicate values minus first IOP readings was -3 to 2.7 mm Hg; for averaged minus lowest: 0 to 3.7 mm Hg; for first minus lowest: 0 to 5 mm Hg. The 95% prediction interval for differences in study group means (n = 160 groups, n = 5 to 11 eyes per group) based on averaged minus first measurements was -1.0 to 0.9 mm Hg with associated SDs reduced by 4% on average. Analysis of previous studies using averaged instead of first IOP values resulted in minimal decreases in SEs of 3-9% (0.03 to 0.09 mm Hg). Of 11 comparisons found significant with averaged data, 2 (18%) were found nonsignificant with first measurements. Of 96 comparisons found nonsignificant with averaged data, 3 (3%) were found significant with first measurements.
Clinical Relevance: With applanation tonometry in ophthalmologically normal dogs, no clinically meaningful difference was found between the first, lowest, or averaged triplicate IOP measurements, but the first reading has a larger variance and hence will result in lower statistical power.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2460/ajvr.21.08.0114 | DOI Listing |