A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Transparent, Hydrophobic Fluorinated Ethylene Propylene Offers Rapid, Robust, and Irreversible Passive Adsorption of Diagnostic Antibodies for Sensitive Optical Biosensing. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Current literature data is scarce and somehow contradictory in respect to the suitability of "nonstick" fluoropolymer surfaces for immobilization of biomolecules. We have previously shown empirically that transparent Teflon fluorinated ethylene propylene (FEP) offers rapid and sensitive optical biosensing of clinically relevant biomarkers. This study shows for the first time a comprehensive experimental analysis of passive adsorption of diagnostic IgG antibodies on actual Teflon FEP microfluidic strips. Full equilibrium isotherms and kinetics for passive adsorption were studied and modeled employing a protein titration method using hundreds of multibore microfluidic strips for a range of temperatures, pH, ionic strengths, and inner diameters, using both polyclonal and monoclonal antibody systems. Results were benchmarked against other plastic hydrophobic and glass hydrophilic capillary surfaces. For the first time, it was shown quantitatively that the hydrophobicity of fluoropolymer surfaces encourages the passive adsorption of diagnostic antibodies for biosensing and is insensitive to the temperature of incubation and to ionic buffer strength. The mass of captured antigen increased with increasing antibody surface coverage up to ∼400 ng/cm, with an optimal adsorbed antibody activity for 45-69% of full monolayer coverage, matching results of other biosensing surfaces. The equilibrium was reached fast, within 5-10 min, and surprisingly both the kinetics and equilibrium of antibody adsorption were dependent on the inner diameter of microcapillaries. This is a novel and relevant result that will generally impact on the design of miniaturized microfluidic biosensing devices. The antibody surface densities obtained with hydrophobic plastic surfaces were 2- to 4-fold lower than for a hydrophilic, glass surface, however the former presented a monolayered adsorption with a higher level of irreversibility, as shown by the adsorption and desorption rates around 1 order of magnitude smaller than for glass, which is highly desirable for biosensing with surface-coated biomolecules.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsabm.9b00214DOI Listing

Publication Analysis

Top Keywords

passive adsorption
16
adsorption diagnostic
12
fluorinated ethylene
8
ethylene propylene
8
offers rapid
8
diagnostic antibodies
8
sensitive optical
8
optical biosensing
8
fluoropolymer surfaces
8
microfluidic strips
8

Similar Publications