Screw Length Associated With Fracture Gapping of Fifth Metatarsal Base Fracture With Intramedullary Screw Fixation: A Cadaveric Study.

J Foot Ankle Surg

Faculty, Limb Preservation and Deformity Correction Fellowship, Fellowship Foot and Ankle Surgeon, The Center for Advanced Orthopaedics, Orthopaedic Associates of Central Maryland Division, Catonsville, MD. Electronic address:

Published: September 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Intramedullary screw fixation is a well-established surgical treatment for fifth metatarsal Jones fractures, due to its minimally invasive nature, and potential early return to activity. Due to the curvature of the fifth metatarsal, optimal length of the screw is needed to prevent gapping at the fracture site. The placement of a straight screw induces straightening of a naturally curved bone. The purpose of this study was to aid surgeons in determining an appropriate screw length for intramedullary fixation of a fifth metatarsal Jones fracture in order to prevent fracture gapping. A transverse osteotomy of the fifth metatarsal was made in 10 cadaver specimens at the level of a traditional Jones fracture. Inserted screws were sequentially increased in length until plantar gapping at the fracture site was noted. The angle (degree) of plantar gapping was measured with each increase in screw length and diameter. The mean length of the cadaveric fifth metatarsals was 73.76 mm (range 67.42-81.73). The mean screw length that caused gapping at the fracture site was 49.89 mm (range 44-55), representing 67.05% (range 61.26-75.35) of the fifth metatarsal length. The correlation coefficient revealed that gapping of the fracture site is most likely to occur when the screw length is 66% the length of the metatarsal length (r = 0.66; 95% confidence interval: 0.06-0.91; p = .04). The angle of the initial gapping was 2.85° (range 2°-4°). With an incremental increase in screw length, the angle was 3.85° (range 3°-6°), and with an incremental increase in screw diameter, the angle was 3.70° (range 2°-5°). Our study demonstrated that screw lengths exceeding 66% of the metatarsal length lead to plantar fracture gapping. Additionally, gapping was accentuated with larger diameter screws due to angle variance.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jfas.2021.12.025DOI Listing

Publication Analysis

Top Keywords

screw length
24
gapping fracture
16
fracture site
16
screw
12
fracture gapping
12
length
12
increase screw
12
metatarsal length
12
fracture
10
gapping
10

Similar Publications

Study Design: This is a retrospective single-center study.

Purpose: The purpose is to investigate the incidence of distal junctional kyphosis (DJK) when fused proximal to the stable sagittal vertebra (SSV) in adolescent idiopathic scoliosis (AIS) patients undergoing selective thoracic fusion.

Methods: We retrospectively reviewed a consecutive cohort of surgically treated AIS patients with Lenke 1-2 A/B curves between 2011 and 2022 with a minimum of 2 years of follow-up.

View Article and Find Full Text PDF

Background: The lateral transpsoas lumbar interbody fusion is associated with transient postoperative anterior thigh and inguinal dysesthesias and hip flexor weakness from manipulation of the psoas and interposed lumbar plexus. However, it remains unclear whether this translates to higher pain scores and opioid requirements.

Methods: Patients who had undergone one- or two-level extreme/direct (XLIF/DLIF), anterior (ALIF), or transforaminal lumbar interbody fusion (TLIF) between January 2018 and December 2023 for degenerative spinal pathology were included.

View Article and Find Full Text PDF

Computer-assisted surgery and planning in percutaneous pelvic screw fixation.

Orthop Traumatol Surg Res

September 2025

CHU de Grenoble-Alpes, Université de Grenoble-Alpes, Laboratoire TIMC-IMAG, Unité de Chirurgie Orthopédique et Traumatologique, CNRS UMR 5525, Boulevard de la Chantourne, 38700 La Tronche, France.

Percutaneous pelvic screwing (PPS) enables fixation of traumatic or atraumatic fractures with little or no displacement, or displaced but reduced fractures, and preventive fixation of primary or secondary tumoral lesions. It is a relatively recent technique, and indications are evolving with progress in pre- and intra-operative imaging. Morbidity is lower than with open surgery.

View Article and Find Full Text PDF

Purpose: To identify factors that contribute to the speed of angular correction in skeletally immature patients with genu varum treated with paraphyseal tension band plates, hypothesizing that screw length and divergence, severity of deformity, and underlying pathology influence the rate and speed of genu varum correction.

Methods: Fifty-three patients (38 males, 15 females) undergoing genu varum correction were included; a total of 138 physes (64 distal femur, 74 proximal tibia) were assessed. The median age at surgery was 37.

View Article and Find Full Text PDF

[Management of forearm shaft fractures : Challenges and solution approaches].

Unfallchirurgie (Heidelb)

September 2025

Klinik für Orthopädie und Unfallchirurgie, Klinikum Nürnberg, Paracelsus Medizinische Privatuniversität, Breslauer Straße 201, 90471, Nürnberg, Deutschland.

Forearm shaft fractures are the most common fractures of the upper extremity in young adults. By definition, these fractures are diaphyseal fractures; however, due to the complex functional unity formed by the forearm shaft during motion both bone forearm fractures are treated as intra-articular fractures [1, 3]. This is why the gold standard of treatment in adults is osteosynthesis.

View Article and Find Full Text PDF