98%
921
2 minutes
20
The fast degradation rate and poor wear resistance of magnesium (Mg) alloys in physiological environments have limited their potential usage as next-generation biodegradable orthopedic implant materials. In this work, femtosecond laser shock peening (fs-LSP) was successfully applied to simultaneously improve the surface mechanical, corrosion, and tribocorrosion properties of WE43 Mg alloys in blood bank buffered saline solution at body temperature. Specifically, the treated surfaces of WE43 Mg alloys via fs-LSP with ultralow pulse energy were investigated under different power densities, confining mediums, and absorbent materials. It was found that the combination of a black tape and a quartz layer gave the optimum peening effect under a power density of 28 GW/cm, which simultaneously strengthened the surface and reduced the corrosion kinetics. In addition, a rapid self-repassivation was observed in fs-LSP-treated WE43 surfaces during tribocorrosion, promising sustained corrosion resistance under mechanical loading, critical to the reliability of load-bearing implants. Finally, the subsurface microstructural evolution and residual stress development in WE43 after fs-LSP were discussed based on the results from transmission electron microscopy analysis and finite element simulations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsabm.1c00826 | DOI Listing |
Biomaterials
September 2025
Medical Research Institute, Department of Orthopedics, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, 510080, China. Electronic address:
Contrary to the traditional strengthening route by adding multiple & high-dosage alloying elements, we here explored extremely compositional and phase-constituent "simplification" in rare earth (RE) containing biodegradable magnesium alloys for better biocompatibility. An ultra-lean Mg-0.1Pr alloy with a multiscale microstructure has been developed through casting and extrusion, which showed well-balanced performances that match the commercial Mg-based orthopedic products.
View Article and Find Full Text PDFRegen Biomater
August 2025
Shi-Changxu Innovation Center for Advanced Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China.
The most significant challenge facing magnesium alloy stents is their ability to withstand complex deformation during their application. To gain a deeper understanding of the impact of stent deformation on the protective capabilities of the coating, this paper presents an amplified stent deformation model. The models were coated with either a low elongation material-Poly(D, L-lactide) (PDLLA) or a high elongation material-Poly(butylene adipate-co-terephthalate) (PBAT), followed by the application of a rapamycin-loaded PLGA as drug-eluting layer.
View Article and Find Full Text PDFLangmuir
September 2025
SERB Sponsered Microfluidics Laboratory, Department of Mechanical Engineering, Jadavpur University, Kolkata, West Bengal 700032, India.
This study investigates the dynamic behavior of water droplets impacting a superhydrophobic surface (SHS) at low Weber numbers ( < 17). SHS is fabricated by a chemical coating process on magnesium AZ31 alloy. The surfaces exhibit a Cassie-Baxter wetting state, showing a contact angle of approximately 155°on the surfaces.
View Article and Find Full Text PDFJ Phys Chem Lett
September 2025
Precise Synthesis and Function Development Key Laboratory of Sichuan Province, College of Chemistry and Chemical Engineering, China West Normal University, Nanchong 637002, PR China.
Herein, CuBiO microspheres were first deposited on TiO nanotube arrays to develop a p-n CuBiO/TiO heterojunction by a facile hydrothermal protocol. The variations in the photoinduced open-circuit potential, photocurrent, and electrochemical parameters of the nickel-plated magnesium alloy (Mg/Ni) demonstrated the remarkably strengthened photoelectrochemical efficiency and photocathodic protection (PCP) capability caused by the CuBiO modification. This enhancement is attributed to establishing a built-in electric field and intensified light absorption in a broadened wavelength spectrum, confirmed by the valence band XPS and ultraviolet-visible spectra.
View Article and Find Full Text PDFACS Appl Mater Interfaces
September 2025
Department of Pediatric Dentistry (Department of Preventive Dentistry), School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University, No.44-1 Wenhua Road West, 250012 Jinan, Shandong, China.
Guided bone regeneration (GBR) is a prominent focus in biomedical materials research, yet few studies address practical clinical needs. GBR membranes must fulfill the "PASS" principles to be effective in surgery, but existing membranes often fall short in balancing antibacterial activity, controlled degradation, osteoinductive potential, and mechanical support. In this study, we employed laser powder bed fusion (LPBF) to fabricate a porous WE43 magnesium alloy scaffold suitable for large alveolar bone defects.
View Article and Find Full Text PDF