A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The clinical value of ultrasonic cardiac output monitor in very-low birth-weight and extremely-low-birth-weight infants undergoing PDA ligation. | LitMetric

The clinical value of ultrasonic cardiac output monitor in very-low birth-weight and extremely-low-birth-weight infants undergoing PDA ligation.

Early Hum Dev

The Second School of Clinical Medicine, Southern Medical University, Guangzhou 510280, China; Department of Neonatology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China. Electronic address:

Published: February 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Cardiorespiratory instability occurs very often in very-low-birth-weight (VLBW) and extremely-low-birth-weight (ELBW) infants undergoing patent ductus arteriosus (PDA) ligation during the early postoperative period. This study aimed to investigate ultrasonic cardiac output monitor (USCOM) as a bedside tool by evaluating the hemodynamic changes in preterm infants following PDA ligation and assessing factors that may influence these changes.

Methods: This was a single-center prospective observational study at a third-level neonatal intensive care unit. A total of 33 infants, including 21 VLBW and 12 ELBW infants, were involved. Hemodynamic measurements were performed in these infants using a USCOM preoperatively as well as 0-1 h, 8-10 h, and 24 h postoperatively.

Results: The PDA ligation was associated with reductions of the left ventricular cardiac output (LVCO) (P < 0.001), cardiac index (P < 0.001), flow time corrected (FTC) (P < 0.001), Smith-Madigan inotropy index (SMII) (P < 0.001), oxygen delivery (DO) (P < 0.001), and oxygen delivery index (DOI) (P < 0.001) and an increase of the systemic vascular resistance index (SVRI) (P < 0.001) at 0-1 h, 8-10 h, and 24 h post-ligation compared with the respective preoperative values. Compared with the respective values at 0-1 h post-ligation, there was no significant difference in the CI, SMII, or FTC at 8-10 h and 24 h post-ligation. However, the SVRI decreased at 8-10 h and 24 h post-ligation. Moreover, the DOI increased at 8-10 h and 24 h post-ligation, and the LVCO and DO increased at 24 h post-ligation.

Conclusion: Our study confirmed that the hemodynamic changes measured by the USCOM were similar to those measured by echocardiography in previous reports. Thus, USCOM is a useful and convenient bedside tool for assessing hemodynamic changes to guide the use of fluids, inotropic agents, and vasopressors and help modify the post-ligation course, and they may be a surrogate for repeated echocardiography during the early post-ligation period in preterm infants or a preliminary screening method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.earlhumdev.2021.105522DOI Listing

Publication Analysis

Top Keywords

pda ligation
16
cardiac output
12
ultrasonic cardiac
8
output monitor
8
infants undergoing
8
elbw infants
8
infants
6
clinical ultrasonic
4
monitor very-low
4
very-low birth-weight
4

Similar Publications