Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Numerous reverse transcription polymerase chain reaction (RT-PCR) tests have emerged over the past year as the gold standard for detecting millions of cases of SARS-CoV-2 reported daily worldwide. However, problems with critical shortages of key reagents such as PCR primers and RNA extraction kits and unpredictable test reliability related to high viral replication cycles have triggered the need for alternative methodologies to PCR to detect specific COVID-19 proteins. Several authors have developed methods based on liquid chromatography with tandem mass spectrometry (LC-MS/MS) to confirm the potential of the technique to detect two major proteins, the spike and the nucleoprotein, of COVID-19. In the present work, an S-Trap mini spin column digestion protocol was used for sample preparation prodromal to LC-MS/MS analysis in multiple reactions monitoring ion mode (MRM) to obtain a comprehensive method capable of detecting different viral proteins. The developed method was applied to n. 81 oro/nasopharyngeal swabs submitted in parallel to quantitative reverse transcription PCR (RT-qPCR) assays to detect RdRP, the S and N genes specific for COVID-19, and the E gene for all , including SARS-CoV-2 (with cycle negativity threshold set to 40). A total of 23 peptides representative of the six specific viral proteins were detected in the monitoring of 128 transitions found to have good ionic currents extracted in clinical samples that reacted differently to the PCR assay. The best instrumental response came from the FLPFQFGR sequence of spike [558-566] peptide used to test the analytical performance of the method that has good sensitivity with a low false-negative rate. Transition monitoring using a targeted MS approach has the great potential to detect the fragmentation reactions of any peptide molecularly defined by a specific amino acid sequence, offering the extensibility of the approach to any viral sequence including derived variants and thus providing insights into the development of new types of clinical diagnostics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8672425PMC
http://dx.doi.org/10.1021/acsomega.1c05587DOI Listing

Publication Analysis

Top Keywords

tandem mass
8
mass spectrometry
8
reverse transcription
8
specific covid-19
8
viral proteins
8
proteins
5
identification sars-cov-2
4
sars-cov-2 proteins
4
proteins nasopharyngeal
4
nasopharyngeal swabs
4

Similar Publications

Plastics are widely used materials composed of polymers and various additives to achieve specific properties. Their composition is often highly complex, particularly in post-consumer plastic waste. As mechanical recycling faces increasing limitations, chemistry-driven strategies are attracting growing interest to improve plastic recovery.

View Article and Find Full Text PDF

Impact of injection solvent composition on 90 pesticides by LC-MS/MS: A data-driven framework for initial method development.

J Chromatogr A

September 2025

Agro-Food Technology and Quality Laboratory, Regional Center of Agricultural Research of Meknes, National Institute of Agricultural Research, Rabat, Morocco. Electronic address:

The composition of the injection solvent is a critical, yet often underestimated, parameter in liquid chromatography-tandem mass spectrometry (LC-MS/MS). This study systematically evaluates the influence of injection solvent on the analysis of 90 pesticides by comparing mixtures of acetonitrile (ACN) with water and buffered mobile phase A (5 mM ammonium formate, 0.1% formic acid) across various ratios (10/90 to 50/50, v/v).

View Article and Find Full Text PDF

HT SpaceM: A high-throughput and reproducible method for small-molecule single-cell metabolomics.

Cell

September 2025

Molecular Systems Biology Unit, European Molecular Biology Laboratory, Heidelberg, Baden-Württemberg 69117, Germany; Department of Pharmacology, University of California, San Diego, La Jolla, CA 92093, USA; Metabolomics Core Facility, European Molecular Biology Laboratory, Heidelberg, Baden-Württe

Single-cell metabolomics (SCM) promises to reveal metabolism in its complexity and heterogeneity, yet current methods struggle with detecting small-molecule metabolites, throughput, and reproducibility. Addressing these gaps, we developed HT SpaceM, a high-throughput SCM method combining cell preparation on custom glass slides, small-molecule matrix-assisted laser desorption ionization (MALDI) imaging mass spectrometry (MS), and batch processing. We propose a unified framework covering quality control, characterization, structural validation, and differential and functional analyses.

View Article and Find Full Text PDF

Food contamination by per- and polyfluoroalkyl substances (PFAS), especially ultra-short-chain (USC) compounds, poses a growing concern due to their environmental persistence and potential health risks. Despite the developing regulatory framework, analytical challenges persist in quantifying polar USC-PFAS in complex content food matrices. This study presents the development and validation of a novel high-performance liquid chromatography coupled to a tandem mass spectrometer (HPLC-MS/MS) method for the accurate determination of USC-PFAS (carbon chain length from one to four, C1-C4) in tomato-based products (i.

View Article and Find Full Text PDF

QuEChERS method of extraction followed by detection with Liquid Chromatograph Mass spectrometry was carried out to determine persistence of tetraniliprole and its metabolite in pigeon pea. The mean recovery of tetraniliprole and its metabolite BCS-CQ 63359 in immature and mature pods, seeds and grains of pigeon pea and soil were in the range of 76.38-105.

View Article and Find Full Text PDF