98%
921
2 minutes
20
Objective: To develop a new method to restore hip rotation center exactly and rapidly in total hip arthroplasty (THA) with the assistance of three dimensional (3D) printing technology and evaluate its clinical and radiological outcomes.
Methods: From March 2014 to July 2018, a total of 17 patients (five hips of four men and 16 hips of 13 women) with end-stage osteoarthritis secondary to developmental dysplasia of the hip who underwent THA were analyzed and followed up retrospectively. The average age is 58.00 ± 8.12 years (range from 45 to 71 years). Simulated operations were performed on 3D printed hip models for preoperative planning. The morphology of Harris fossa and acetabular notches were recognized and restored to locate the acetabular center. The size of bone defect was measured by the bone wax method. The agreement on the size of acetabular cup and bone defect between simulated operations and actual operations were analyzed. Harris Hip Score (HHS) was used to evaluate the recovery of hip joint function. The vertical distance and horizontal distance of the rotation center on the pelvis plain radiograph were measured, which were used to assess the efficacy of restoring hip rotation center and acetabular cup migration.
Results: The mean sizes of bone defect in simulated operations and THA were 4.58 ± 2.47 cm and 4.55 ± 2.57 cm respectively. There was no significant difference statistically between the sizes of bone defect in simulated operations and the actual sizes of bone defect in THA (t = 0.03, P = 0.97). The sizes of the acetabular cup of simulated operations on 3D print models showed a high rate of coincidence with the actual sizes in the operations (ICC = 0.93). All 17 patients were available for clinical and radiological follow-up. The average follow-up time was 18.35 ± 6.86 months (range, 12-36 months. The average HHS of the patients was improved from (38.33 ± 6.07) preoperatively to the last follow-up (88.61 ± 3.44) postoperatively. The mean vertical and horizontal distances of hip rotation center on the pelvic radiographs were restored to 15.12 ± 1.25 mm and 32.49 ± 2.83 mm respectively. No case presented dislocation or radiological signs of loosening until last follow-up.
Conclusions: The application of 3D printing technology facilitates orthopedists to recognize the morphology of Harris fossa and acetabular notches, locate the acetabular center and restore the hip rotation center rapidly and accurately.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8755880 | PMC |
http://dx.doi.org/10.1111/os.13183 | DOI Listing |
Biochem Biophys Rep
December 2025
Henan University of Chinese Medicine, Zhengzhou, 450046, China.
Introduction: 5-Hydroxymethyl furfural (5-HMF) is a furan compound with a molecular formula of CHO. Studies have found that 5-HMF has many pharmacological effects, such as improving hemorheology, anti-inflammatory, antioxidant activity and anti-myocardial ischemia. Identifying the preventive effect of 5-HMF against ischemic stroke and its possible mechanism was the aim of this investigation.
View Article and Find Full Text PDFMed Educ
September 2025
University of Miami Gordon Center for Simulation and Innovation in Medical Education, Miami, Florida, USA.
Introduction: Speaking up about medical errors is a critical behaviour for medical students, as it plays a vital role in enhancing patient safety. Few studies have explored the drivers and barriers affecting their willingness to speak up in clinical training, particularly within hierarchical Asian cultures. The purpose of this study was to explore drivers and barriers shaping medical students' speaking up behaviours about medical errors to inform education, mentorship and patient safety practices.
View Article and Find Full Text PDFAesthetic Plast Surg
September 2025
Department of Otolaryngology, Masih Daneshvari Hospital, Neyavran, Darabad, Tehran, Iran.
Nasal alar reconstruction is complex due to the region's anatomy and aesthetic importance. This report describes repairing a small, full-thickness alar rim defect in a 36-year-old man using a rotational columellar skin flap with septal cartilage grafting. This single-stage technique achieved good color match, symmetry, and minimal donor-site morbidity.
View Article and Find Full Text PDFActa Ortop Mex
September 2025
Instituto Nacional de Rehabilitación «Luis Guillermo Ibarra Ibarra». Ciudad de México. México.
Rotator cuff injuries are common and procedures of repair have evolved from open techniques to minimally invasive and arthroscopic ones. Despite these advances, the biomechanics, biology, and value of transosseous repairs remain superior, leading to the development of innovative devices that enable the utilization of this technique without the use of anchors, improving both the efficiency and safety of the procedure. This article reviews the latest advances in transosseous rotator cuff repair, highlighting its biomechanical advantages, as well as the factors that enhance recovery and offer more consistent long-term outcomes.
View Article and Find Full Text PDFJ Neurophysiol
September 2025
School of Psychological and Cognitive Sciences, Peking University, Beijing, China.
Limiting cognitive resources negatively impacts motor learning, but its cognitive mechanism is still unclear. Previous studies failed to differentiate its effect on explicit (or cognitive) and implicit (or procedural) aspects of motor learning. Here, we designed a dual-task paradigm requiring participants to simultaneously perform a visual working memory task and a visuomotor rotation adaptation task to investigate how cognitive load differentially impacted explicit and implicit motor learning.
View Article and Find Full Text PDF