Nasal continuous positive airway pressure (nCPAP) is the standard non-invasive respiratory support for newborns with respiratory distress. Nasal injury is a common problem with the interfaces used. To compare the incidence and severity of nasal injury in neonates with respiratory distress and supported on nCPAP with Hudson prong or RAM cannula with Cannulaide, a semipermeable membrane. This is an open-label, parallel-arm, gestational age-stratified, bi-centric, randomized control trial including neonates between 28 and 34 weeks gestational age and birth weight > 1000 g needing nCPAP. The size of the interface was chosen as per the manufacturer's recommendation. Of the 229 neonates enrolled, 112 were randomized to RAM cannula with Cannulaide and 117 to Hudson prong. The baseline characteristics were similar. Any nasal injury at CPAP removal was significantly lower in the RAM cannula with Cannulaide group [6 (5.4%) vs. 31 (26.4%); risk ratio-0.77 (95% CI 0.69-0.87); p = 0.0001]. The incidence of moderate to severe nasal injury, need for mechanical ventilation within 72 h of age, duration of oxygen, and requirement of nCPAP for > 3 days were similar. For preterm infants on nCPAP, RAM cannula with Cannulaide, compared to Hudson prongs, decreases nasal injury without increasing the need for mechanical ventilation.Trail registration: CTRI/2019/03/018333, http://www.ctri.nic.in .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8651736PMC
http://dx.doi.org/10.1038/s41598-021-02988-4DOI Listing

Publication Analysis

Top Keywords

ram cannula
20
cannula cannulaide
20
nasal injury
20
hudson prongs
8
nasal continuous
8
continuous positive
8
positive airway
8
airway pressure
8
preterm infants
8
respiratory distress
8

Similar Publications

Objective: To compare the efficacy of nasopharyngeal (NP) prongs and RAM cannula in preventing the need for invasive ventilation among preterm neonates receiving noninvasive positive pressure ventilation (NIPPV).

Study Design: This was an open-label, randomized controlled trial conducted in the neonatal intensive care unit of a tertiary care hospital in India. A total of 150 neonates born at 28 to 36 weeks of gestation who required NIPPV were randomized to receive NIPPV via either NP prongs or a RAM cannula.

View Article and Find Full Text PDF

Background: Non-Invasive Ventilation (NIV) is the first choice approach in neonates with sufficient respiratory effort that require respiratory support. The type of nasal interface used in NIV affects both efficacy and patient comfort. The aim of this study is to investigate the effects of different nasal interfaces used in NIV support on neonatal patient comfort.

View Article and Find Full Text PDF

Objectives: To compare the efficacy and safety of RAM cannula with short binasal prongs (SBPs) as nasal interfaces in preterm infants requiring nasal continuous positive airway pressure (nCPAP) or nasal intermittent positive pressure ventilation (NIPPV).

Methods: The authors searched electronic databases (Medline, Embase, and Web of Science) and trial registries from inception until March 15, 2024, for randomized controlled trials (RCTs) comparing the RAM cannula with SBP for delivering nCPAP/NIPPV. They performed a random-effects meta-analysis using RevMan 5.

View Article and Find Full Text PDF

Background Newborns frequently experience respiratory distress (RD), necessitating preventive management during transportation. The use of Continuous Positive Airway Pressure (CPAP) is crucial in mitigating RD in neonates, particularly during transit. This study aims to assess the feasibility and efficacy of utilizing a RAM cannula (Neotech Products, Valencia, USA) with a T-piece resuscitator to deliver CPAP during neonatal transport.

View Article and Find Full Text PDF