A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Segmentation of the Aorta and Pulmonary Arteries Based on 4D Flow MRI in the Pediatric Setting Using Fully Automated Multi-Site, Multi-Vendor, and Multi-Label Dense U-Net. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Automated segmentation using convolutional neural networks (CNNs) have been developed using four-dimensional (4D) flow magnetic resonance imaging (MRI). To broaden usability for congenital heart disease (CHD), training with multi-institution data is necessary. However, the performance impact of heterogeneous multi-site and multi-vendor data on CNNs is unclear.

Purpose: To investigate multi-site CNN segmentation of 4D flow MRI for pediatric blood flow measurement.

Study Type: Retrospective.

Population: A total of 174 subjects across two sites (female: 46%; N = 38 healthy controls, N = 136 CHD patients). Participants from site 1 (N = 100), site 2 (N = 74), and both sites (N = 174) were divided into subgroups to conduct 10-fold cross validation (10% for testing, 90% for training).

Field Strength/sequence: 3 T/1.5 T; retrospectively gated gradient recalled echo-based 4D flow MRI.

Assessment: Accuracy of the 3D CNN segmentations trained on data from single site (single-site CNNs) and data across both sites (multi-site CNN) were evaluated by geometrical similarity (Dice score, human segmentation as ground truth) and net flow quantification at the ascending aorta (Qs), main pulmonary artery (Qp), and their balance (Qp/Qs), between human observers, single-site and multi-site CNNs.

Statistical Tests: Kruskal-Wallis test, Wilcoxon rank-sum test, and Bland-Altman analysis. A P-value <0.05 was considered statistically significant.

Results: No difference existed between single-site and multi-site CNNs for geometrical similarity in the aorta by Dice score (site 1: 0.916 vs. 0.915, P = 0.55; site 2: 0.906 vs. 0.904, P = 0.69) and for the pulmonary arteries (site 1: 0.894 vs. 0.895, P = 0.64; site 2: 0.870 vs. 0.869, P = 0.96). Qs site-1 medians were 51.0-51.3 mL/cycle (P = 0.81) and site-2 medians were 66.7-69.4 mL/cycle (P = 0.84). Qp site-1 medians were 46.8-48.0 mL/cycle (P = 0.97) and site-2 medians were 76.0-77.4 mL/cycle (P = 0.98). Qp/Qs site-1 medians were 0.87-0.88 (P = 0.97) and site-2 medians were 1.01-1.03 (P = 0.43). Bland-Altman analysis for flow quantification found equivalent performance.

Data Conclusion: Multi-site CNN-based segmentation and blood flow measurement are feasible for pediatric 4D flow MRI and maintain performance of single-site CNNs.

Level Of Evidence: 3 TECHNICAL EFFICACY: Stage 2.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9106805PMC
http://dx.doi.org/10.1002/jmri.27995DOI Listing

Publication Analysis

Top Keywords

flow mri
8
mri pediatric
8
multi-site multi-vendor
8
multi-site cnn
8
flow
6
multi-site
5
segmentation
4
segmentation aorta
4
aorta pulmonary
4
pulmonary arteries
4

Similar Publications