Dual-Energy CT Perfusion of Invasive Tumor Front in Non-Small Cell Lung Cancers.

Radiology

From the Departments of Thoracic Imaging (J.D., J.B.F., J.R., M.R.J.) and Biomedical Statistics (A.D., V.D.), ULR 2694 Evaluation des Technologies de Santé et des Pratiques Médicales (METRICS), and Department of Pathology (M.C.C.), CHU Lille, University of Lille, 59000 Lille, France; Department of

Published: February 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background Active endothelial cell proliferation occurs at the tumor edge, known as the invading-tumor front. This study focused on perfusion analysis of non-small cell lung cancers. Purpose To analyze dual-phase, dual-energy CT perfusion according to the degree of tumor hypoxia. Materials and Methods This prospective study was performed 2016-2017. A two-phase dual-energy CT protocol was obtained for consecutive participants with operable non-small cell lung cancer. The first pass and delayed iodine concentration within the tumor and normalized iodine uptake, corresponding to the iodine concentration within the tumor normalized to iodine concentration within the aorta, were calculated for the entire tumor and within three peripheral layers automatically segmented (ie, 2-mm-thick concentric subvolumes). The expression of the membranous carbonic anhydrase (mCA) IX, a marker of tumor hypoxia, was assessed in tumor specimens. Comparative analyses according to the histologic subtypes, type of resected tumors, and mCA IX expression were performed. Results There were 33 mCA IX-positive tumors and 16 mCA IX-negative tumors. In the entire tumor, the mean normalized iodine uptake was higher on delayed than on first-pass acquisitions (0.35 ± 0.17 vs 0.13 ± 0.15, respectively; < .001). A single layer, located at the edge of the tumor, showed higher values of the iodine concentration (median, 0.53 mg/mL vs 0.21 mg/mL, respectively; = .03) and normalized iodine uptake (0.04 vs 0.02, respectively; = .03) at first pass in mCA IX-positive versus mCA IX-negative tumors. Within this layer, a functional profile of neovascularization was found in 23 of 33 (70%) of mCA IX-positive tumors, and the median mCA IX score of these tumors was higher than in tumors with a nonfunctional profile of neovascularization (median mCA IX score, 20 vs 2, respectively; = .03). Conclusion A two-phase dual-energy CT examination depicted higher perfusion between the tumor edge and lung parenchyma in hypoxic tumors. © RSNA, 2021 See also the editorial by Murphy and Ryan in this issue.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2021210600DOI Listing

Publication Analysis

Top Keywords

iodine concentration
16
normalized iodine
16
non-small cell
12
cell lung
12
tumor normalized
12
iodine uptake
12
mca ix-positive
12
tumor
11
mca
9
dual-energy perfusion
8

Similar Publications

The scope of this study was to characterize the iodine nutritional status of pregnant Brazilian women according to biochemical and dietary markers. It involved a cross-sectional study of 2,376 pregnant women. A semi-structured questionnaire was used to characterize the population.

View Article and Find Full Text PDF

This study introduces a novel optimization framework for cranial three-dimensional rotational angiography (3DRA), combining the development of a brain equivalent in-house phantom with Figure of Merit (FOM) a quantitative evaluation method. The technical contribution involves the development of an in-house phantom constructed using iodine-infused epoxy and lycal resins, validated against clinical Hounsfield Units (HU). A customized head phantom was developed to simulate brain tissue and cranial vasculature for 3DRA optimization.

View Article and Find Full Text PDF

Background: Identifying the etiology of acute ischemic stroke (AIS) is critical for secondary prevention and treatment choice in stroke patients. This study aimed to investigate the dual-energy computed tomography (DECT) quantitative thrombus parameters associated with cardioembolic (CE) stroke and develop a nomogram that combines DECT and clinical data to identify CE stroke.

Methods: We retrospectively reviewed all consecutive patients from January 2020 to July 2022 with anterior circulation stroke and proximal intracranial occlusions.

View Article and Find Full Text PDF

With the rapid development of the nuclear medicine business worldwide, the removal of iodine-131 from specific contaminated environments to protect public health has important application prospects. In this study, the surface decontamination mechanism of Ce(IV)/HNO3 as a decontaminant for iodine-131-contaminated nonmetallic materials was investigated by using an orthogonal experimental method and scanning electron microscopy (SEM). During the preparation experiments with the contaminated materials, both quartz glass and ceramics reached peak activity concentration levels at 4 h of adsorption (contamination) by using immersion; the decontamination factor (DF) was selected as the test index for the decontamination experiments.

View Article and Find Full Text PDF

The consumption of kombu plays an important role in the traditional dietary habits of East-Asian countries. However, data on the metabolic profile of kombu-derived iodine remain limited. Totally, 20 Chinese participants (age 19.

View Article and Find Full Text PDF