Article Abstract

Purpose: To compare the accuracy of the Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Kane, and SRK/T formulas for intraocular lens power calculation in patients with high axial myopia.

Methods: In this retrospective study, 175 eyes (175 patients) that underwent uneventful cataract surgery were enrolled. According to the axial length (AL), the eyes were divided into long AL (26 ⩽ AL < 28 mm), super long AL (28 ⩽ AL < 30 mm), and extremely long AL (⩾ 30 mm). The mean absolute prediction errors (MAE) 3 months postoperatively and the percentage of eyes within different prediction error were compared, followed by subgroup analysis.

Results: The MAE and percentage of eyes within ±0.50 diopters (D) of the five formulas were as follows: Barrett Universal II (0.342, 74.9%), EVO 2.0 (0.314, 82.3%), Haigis (0.336, 74.9%), Kane (0.318, 78.9%), and SRK/T (0.398, 69.7%) ( = .552 and .071, respectively). Although no significant difference was found among the five formulas in the super and extremely long AL groups ( = .792 and .227, respectively), the EVO 2.0 formula achieved the highest accuracy (88.9%, 72 of 81) in the long AL group ( = .049). Moreover, the accuracy of the EVO 2.0 and Haigis formulas was stable, regardless of AL. The SRK/T formula showed a negative trend in the long and super long AL groups, whereas the Barrett Universal II, Kane, and SRK/T formulas showed positive trends in the extremely long AL group.

Conclusions: Overall, the EVO 2.0 and Kane formulas achieved better results in patients with high axial myopia, whereas the other three formulas showed slightly poor outcomes. .

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20210712-08DOI Listing

Publication Analysis

Top Keywords

high axial
12
barrett universal
12
extremely long
12
power calculation
8
formulas
8
axial myopia
8
evo haigis
8
kane srk/t
8
srk/t formulas
8
patients high
8

Similar Publications

Progressive lifespan modifications in the corpus callosum following a single concussion in juvenile male mice monitored by diffusion MRI.

Exp Neurol

September 2025

CNRS UMR 5536 RMSB, University of Bordeaux, Bordeaux, France; Basic Science Department, Loma Linda University School of Medicine, Loma Linda, CA, USA; CNRS UMR 7372 CEBC, La Rochelle University, Villiers-en-Bois, France.

Introduction: The vulnerability of white matter (WM) in acute and chronic moderate-severe traumatic brain injury (TBI) has been established. In concussion syndromes, including preclinical rodent models, lacking are comprehensive longitudinal studies spanning the mouse lifespan. We previously reported early WM modifications using clinically relevant neuroimaging and histological measures in a model of juvenile concussion at one month post injury (mpi) who then exhibited cognitive deficits at 12mpi.

View Article and Find Full Text PDF

Background And Aim: The incisive (nasopalatine) canal is an important anatomical structure of the anterior maxilla. It holds significance for surgeries and implant placement in the central incisor region. The size, shape, and relation with surrounding bones may vary by age, gender, and ethnicity.

View Article and Find Full Text PDF

The Scolioscope: a home detection tool for measuring axial trunk rotation in scoliosis-a validation study.

Spine Deform

September 2025

Department of Orthopedics and Sports Medicine, Erasmus MC, University Medical Center Rotterdam, Dr Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.

Purpose: Screening for adolescent idiopathic scoliosis (AIS) using the Adam Forward Bending Test (AFBT) remains controversial, resulting in the discontinuation of scoliosis screening in the Netherlands. This study aims to validate the Scolioscope, a simplified version of the Scoliometer, for detecting scoliosis in a home setting.

Methods: A validation study was conducted at the orthopedic outpatient clinic of Erasmus Medical Center Sophia Children's Hospital in Rotterdam, the Netherlands.

View Article and Find Full Text PDF

A novel medium-current (up to 20 mA), low normalized beam emittance (<1 π mm mrad) electron cyclotron resonance microwave H+ ion source has been developed at the Center for Energy Research in Budapest, Hungary. This high-stability design targets an energy ripple below 1% while delivering a continuous or pulsed proton beam with adjustable pulse duration (0.1-10 ms) and frequency (0.

View Article and Find Full Text PDF

Clear cell renal cell carcinoma (ccRCC) is a malignant tumor, originating from the renal epithelium, and accounts for ~85% of RCC cases. The present study aimed to validate the efficacy of an MRI deep learning (DL) model to preoperatively predict the pathological grading of ccRCC. Therefore, a DL algorithm was constructed and trained using diffusion weighted imaging (DWI) and diffusion kurtosis imaging (DKI) sequence images.

View Article and Find Full Text PDF