Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Cochlear implant technology is a well-known approach to help deaf individuals hear speech again and can improve speech intelligibility in quiet conditions; however, it still has room for improvement in noisy conditions. More recently, it has been proven that deep learning-based noise reduction, such as noise classification and deep denoising autoencoder (NC+DDAE), can benefit the intelligibility performance of patients with cochlear implants compared to classical noise reduction algorithms.

Objective: Following the successful implementation of the NC+DDAE model in our previous study, this study aimed to propose an advanced noise reduction system using knowledge transfer technology, called NC+DDAE_T; examine the proposed NC+DDAE_T noise reduction system using objective evaluations and subjective listening tests; and investigate which layer substitution of the knowledge transfer technology in the NC+DDAE_T noise reduction system provides the best outcome.

Methods: The knowledge transfer technology was adopted to reduce the number of parameters of the NC+DDAE_T compared with the NC+DDAE. We investigated which layer should be substituted using short-time objective intelligibility and perceptual evaluation of speech quality scores as well as t-distributed stochastic neighbor embedding to visualize the features in each model layer. Moreover, we enrolled 10 cochlear implant users for listening tests to evaluate the benefits of the newly developed NC+DDAE_T.

Results: The experimental results showed that substituting the middle layer (ie, the second layer in this study) of the noise-independent DDAE (NI-DDAE) model achieved the best performance gain regarding short-time objective intelligibility and perceptual evaluation of speech quality scores. Therefore, the parameters of layer 3 in the NI-DDAE were chosen to be replaced, thereby establishing the NC+DDAE_T. Both objective and listening test results showed that the proposed NC+DDAE_T noise reduction system achieved similar performances compared with the previous NC+DDAE in several noisy test conditions. However, the proposed NC+DDAE_T only required a quarter of the number of parameters compared to the NC+DDAE.

Conclusions: This study demonstrated that knowledge transfer technology can help reduce the number of parameters in an NC+DDAE while keeping similar performance rates. This suggests that the proposed NC+DDAE_T model may reduce the implementation costs of this noise reduction system and provide more benefits for cochlear implant users.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587190PMC
http://dx.doi.org/10.2196/25460DOI Listing

Publication Analysis

Top Keywords

noise reduction
32
reduction system
24
knowledge transfer
20
cochlear implant
16
transfer technology
16
proposed nc+ddae_t
16
implant users
12
nc+ddae_t noise
12
number parameters
12
noise
9

Similar Publications

An ongoing goal of top-down mass spectrometry is to increase the performance for larger proteins. Using higher energy activation methods, like 193 nm ultraviolet photodissociation (UVPD), offers the potential to cause more extensive fragmentation of large proteins and thereby yield greater sequence coverage. Obtaining high sequence coverage requires confident identification and assignment of fragment ions, and this process is hampered by spectral congestion and low signal-to-noise ratio (S/N) of the fragment ions.

View Article and Find Full Text PDF

Background: Stroke, frequently associated with carotid artery disease, is evaluated using carotid computed tomography angiography (CTA). Dual-energy CTA (DE-CTA) enhances imaging quality but presents challenges in maintaining high image clarity with low-dose scans.

Objectives: To compare the image quality of 50 keV virtual monoenergetic images (VMI) generated using Deep Learning Image Reconstruction (DLIR) and Adaptive Statistical Iterative Reconstruction-V (ASIR-V) algorithms under a triple-low scanning protocol in carotid CTA.

View Article and Find Full Text PDF

Obstructive Sleep Apnea is a prevalent condition linked to various health issues, including cardiovascular disease and cognitive decline. This systematic review evaluates the comparative efficacy and patient adherence of two primary treatment modalities: Continuous Positive Airway Pressure and Mandibular Advancement Devices. This review incorporates studies from 2004 to 2024, applying Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and focusing on randomised controlled trials.

View Article and Find Full Text PDF

Cervical cancer remains a significant cause of female mortality worldwide, primarily due to abnormal cell growth in the cervix. This study proposes an automated classification method to enhance detection accuracy and efficiency, addressing contrast and noise issues in traditional diagnostic approaches. The impact of image enhancement on classification performance is evaluated by comparing transfer learning-based Convolutional Neural Network (CNN) models trained on both original and enhanced images.

View Article and Find Full Text PDF

Introduction: Submarine environments pose unique challenges to maintaining physical activity and exercise routines due to confined spaces, demanding schedules, and limited resources. This study investigated submariners' physical activity patterns, sleep quality, and perceived exercise barriers in both land- and sea-based settings, with the goal of informing targeted health interventions.

Materials And Methods: Ethics approval was granted by the Defence Science and Technology Group and Edith Cowan University review panels.

View Article and Find Full Text PDF