A Finite Element Analysis Model is Suitable for Biomechanical Analysis of Orbital Development.

J Craniofac Surg

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, and Beijing Ophthalmology Visual Science Key Lab, Beijing.

Published: October 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The authors investigated orbital bone development in congenital microphthalmia (CM) using a three-dimensional finite element analysis model, after the orbital dimension deficiency was improved with a self-inflating hydrogel expander implant.Data of a 2-year-old male CM patient were examined. The orbital structure, eyeball, eye muscles, and self-inflating hydrogel expander were constructed according to computed tomography examination data. The effects of self-expanding spherical hydrogel at various locations in the muscle cone on orbital bone development were examined using 3-mL self-expanding expanders placed at shallow (model 1: 2 mm depth) and deep (model 2: 8 mm depth) muscle cone positions. This model simulated the hydrogel expansion process; the orbital bone biomechanics and radial displacement nephograms were obtained when the hydrogel volume increased 3, 5, 7, and 9 times and analyzed.The orbital bone biomechanics were concentrated at the medial orbital wall center, gradually spreading to the whole orbital wall. Biomechanics and radial displacement of the inferior temporal and lateral distal orbital wall region were the most significant, and were more significant in model 1 than in model 2.Finite element analysis is suitable for the biomechanical analysis of orbital development in CM. The shallow position inside CM patients' muscle cone is the optimal site for hydrogel implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000007558DOI Listing

Publication Analysis

Top Keywords

orbital bone
16
element analysis
12
muscle cone
12
orbital wall
12
orbital
11
finite element
8
analysis model
8
suitable biomechanical
8
biomechanical analysis
8
analysis orbital
8

Similar Publications

Objective: This study presents a comparative analysis of outcomes of lateral orbital wall decompression performed using ultrasonic bone removal with standard and modified techniques.

Material And Methods: The study included 78 patients (109 orbits) with exophthalmos without visual impairment (subgroups 1A and 1B) and with optic neuropathy (ON) due to thyroid eye disease (TED) (subgroups 2A and 2B). Lateral wall decompression (LWD) was performed using ultrasonic bone removal with a modified (=58, patient subgroups 1A and 2A) or standard (=51, subgroups 1B and 2B) technique.

View Article and Find Full Text PDF

Background: Dental rehabilitation is considered challenging to achieve whenever composite scapulo-dorsal free flaps are used to reconstruct medium-to-large maxillary defects due to the fact that bone quality and quantity may be low, which may preclude placement of conventional dental implants. In such cases, current options for dental rehabilitation include printed patient-specific subperiosteal implants or zygomatic implants.

Methods: The authors report three cases of maxillary tumour resections that led to medium-to-large defects reconstructed using composite scapulo-dorsal free flaps.

View Article and Find Full Text PDF

This study was performed to evaluate the amount of bone implant engagement (BIE) of zygomatic implants (ZIs) at the malar bone level and its correlation with the ZAGA classification (zygoma anatomy-guided approach). One hundred ZIs placed in 32 patients with severe maxillary atrophy using a fully digital protocol were assessed: 80 placed in pairs (40 anterior (AI), 40 posterior (PI)) and 20 as single ZIs (SI). The ZAGA classification was determined preoperatively.

View Article and Find Full Text PDF

3D-CT Study of Buccal Fat Pad Volume in Patients with Prominent Zygoma.

J Stomatol Oral Maxillofac Surg

September 2025

Department of Medical Cosmetology and Plastic Surgery, Affiliated Hospital of Southwest Jiaotong University, The Third People's Hospital of Chengdu, Chengdu, Sichuan, China. Electronic address:

Objective: To compare the symmetry of bilateral buccal fat pad(BFP) volumes in patients with prominent zygomatic bones before surgery.

Methods: Fifty cosmetic female patients were selected and scanned using computed tomography. Based on the symmetry of the patients' zygomatic bones prior to surgery, they were divided into the Sym group and the Asym group.

View Article and Find Full Text PDF

Fitting accuracy of preformed osteosynthesis plates for zygomaticomaxillary complex fractures.

J Craniomaxillofac Surg

September 2025

Department of Oral and Maxillofacial Surgery, Amsterdam UMC, Amsterdam, University of Amsterdam, the Netherlands.

Background: Preformed osteosynthesis plates are a novel treatment option for the fixation of zygomaticomaxillary complex (ZMC) fractures. A preformed plate may improve the reduction accuracy, as an accurate fit and sufficient fixation possibilities are provided.

Purpose: This study aimed to evaluate the virtual fitting accuracy of preformed anatomical osteosynthesis zygoma plates and to assess whether their shape and size are adequate for ZMC fracture treatment.

View Article and Find Full Text PDF