A finger-driven disposable micro-platform based on isothermal amplification for the application of multiplexed and point-of-care diagnosis of tuberculosis.

Biosens Bioelectron

Beijing Advanced Innovation Center for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China; School of Biomedical Engineering, Research and Engineering Center of Biomedical Material

Published: January 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Tuberculosis (TB) remains the high-risk infectious pathogen that caused global pandemic and high mortality, particularly in the areas lack in health resources. Clinical TB screening and diagnosis are so far mainly conducted on limited types of commercial platforms, which are expensive and require skilled personnel. In this work, we introduced a low-cost and portable finger-driven microfluidic chip (named Fd-MC) based on recombinase polymerase amplification (RPA) for rapid on-site detection of TB. After injection of the pre-treated sample solution, the pre-packaged buffer was driven by the pressure generated by the finger-actuated operation to accomplish sequential processes of diagnosis in a fully isolated microchannel. An in-situ fluorescence strategy based on FAM-probe was implemented for on-chip results read-out though a hand-held UV lamp. Hence, the Fd-MC proved unique advantageous for avoiding the risk of infection or environmental contamination. In addition, the Fd-MC was designed for multiplexed detection, which is able to not only identify TB/non-TB infection, but also differentiate between human Mycobacterium tuberculosis and Mycobacterium bovis. The platform was verified in 37 clinical samples, statistically with 100% specificity and 95.2% sensitivity as compared to commercial real-time RPA. Overall, the proposed platform eliminates the need on external pumps and skilled personnel, holding promise to POC testing in the resource-limited area.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2021.113663DOI Listing

Publication Analysis

Top Keywords

skilled personnel
8
finger-driven disposable
4
disposable micro-platform
4
micro-platform based
4
based isothermal
4
isothermal amplification
4
amplification application
4
application multiplexed
4
multiplexed point-of-care
4
point-of-care diagnosis
4

Similar Publications

The adoption of robotic pancreatectomy has grown significantly in recent years, driven by its potential advantages in precision, minimally invasive access, and improved patient recovery. However, mastering these complex procedures requires overcoming a substantial learning curve, and the role of structured mentoring in facilitating this transition remains underexplored. This systematic review and meta-analysis aimed to comprehensively evaluate the number of cases required to achieve surgical proficiency, assess the impact of mentoring on skill acquisition, and analyze how outcomes evolve throughout the learning process.

View Article and Find Full Text PDF

Background: Nurses remain critical in newborn care delivery in Kenya. However, persistent nurse shortages in newborn units limit their ability to provide optimal care. Staff shortages contribute to missed care and high workloads, negatively impacting the motivation and well-being of nurses.

View Article and Find Full Text PDF

There are many benefits for students who participate in undergraduate research experiences, including increased retention and persistence in science, technology, engineering, and mathematics (STEM). By doing research, minoritized students increase their likelihood of pursuing graduate school and STEM careers. The benefits of research experiences are partially mediated by students' interactions with their faculty research mentor.

View Article and Find Full Text PDF

Magnet Program Directors: Advancing Quality Through Excellence in Professional Development.

J Nurses Prof Dev

September 2025

Amy Milner, DNP, RN, NPD-BC, AnMed, Anderson, South Carolina.

Nursing professional development practitioners functioning as Magnet® Program Directors (MPDs) play crucial roles surrounding nurse-sensitive indicators. Focusing on outperforming nurse-sensitive indicators, the role of the MPD is a vitally important one that requires multiple skill sets, including clinical knowledge, expertise in project management, and skill in collaborating to directly impact patient outcomes. The Nursing Professional Development Practice Model outlines roles that MPDs can use to advance nursing excellence, promote professional practice, and drive quality outcomes.

View Article and Find Full Text PDF