There is no universally agreed set of anatomical structures that must be identified on ultrasound for the performance of ultrasound-guided regional anesthesia (UGRA) techniques. This study aimed to produce standardized recommendations for core (minimum) structures to identify during seven basic blocks. An international consensus was sought through a modified Delphi process. A long-list of anatomical structures was refined through serial review by key opinion leaders in UGRA. All rounds were conducted remotely and anonymously to facilitate equal contribution of each participant. Blocks were considered twice in each round: for "orientation scanning" (the dynamic process of acquiring the final view) and for the "block view" (which visualizes the block site and is maintained for needle insertion/injection). Strong recommendations for inclusion were made if ≥75% of participants rated a structure as "definitely include" in any round. Weak recommendations were made if >50% of participants rated a structure as "definitely include" or "probably include" for all rounds (but the criterion for "strong recommendation" was never met). Thirty-six participants (94.7%) completed all rounds. 128 structures were reviewed; a "strong recommendation" is made for 35 structures on orientation scanning and 28 for the block view. A "weak recommendation" is made for 36 and 20 structures, respectively. This study provides recommendations on the core (minimum) set of anatomical structures to identify during ultrasound scanning for seven basic blocks in UGRA. They are intended to support consistent practice, empower non-experts using basic UGRA techniques, and standardize teaching and research.

Download full-text PDF

Source
http://dx.doi.org/10.1136/rapm-2021-103004DOI Listing

Publication Analysis

Top Keywords

anatomical structures
16
structures identify
12
basic blocks
12
international consensus
8
structures
8
identify ultrasound
8
ultrasound performance
8
ultrasound-guided regional
8
regional anesthesia
8
set anatomical
8

Similar Publications

An Investigation of Hyperostosis Frontalis Interna in a Modern Anatomical Body Donor Population.

Clin Anat

September 2025

Department of Communication Disorders and Sciences, Rush University Medical Center, Chicago, Illinois, USA.

This research sought to examine the prevalence and severity of hyperostosis frontalis interna (HFI) in the Chicagoland anatomical body donor population. The study further aimed to elucidate potential demographic risk factors for HFI, including sex, age at death, and structural vulnerability index (SVI), as well as any common comorbidities, as gleaned from death certificates. HFI is an irregular bony overgrowth of the endocranial surface of the frontal bone.

View Article and Find Full Text PDF

Background: Nodular hidradenoma (NH) is a rare benign adnexal tumor originating from sweat glands, often misdiagnosed due to nonspecific clinical manifestations. Ultrasonography (US) plays a critical role in the diagnosis of skin tumors, yet systematic descriptions of its sonographic features remain limited.

Objective: This study aims to investigate the very-high-frequency (VHF) characteristics of eccrine nodular hidradenoma (ENH) and establish key imaging criteria to differentiate it from other cutaneous/subcutaneous lesions.

View Article and Find Full Text PDF

Rapid Atrial Pacing After TAVI for Pacemaker Prediction.

Rev Cardiovasc Med

August 2025

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.

Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.

View Article and Find Full Text PDF

Background: Four-dimensional magnetic resonance imaging (4D-MRI) holds great promise for precise abdominal radiotherapy guidance. However, current 4D-MRI methods are limited by an inherent trade-off between spatial and temporal resolutions, resulting in compromised image quality characterized by low spatial resolution and significant motion artifacts, hindering clinical implementation. Despite recent advancements, existing methods inadequately exploit redundant frame information and struggle to restore structural details from highly undersampled acquisitions.

View Article and Find Full Text PDF

This study aimed to develop an acellular dermal matrix derived from tilapia skin and evaluate its potential as a bioscaffold for skin wound repair. Structural and compositional changes before and after decellularisation were assessed through histological staining, electron microscopy and immunological analysis. The matrix exhibited low immunogenicity, preserved extracellular matrix architecture and retained key bioactive components.

View Article and Find Full Text PDF