A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Agreement of Bioreactance Cardiac Output Monitoring With Thermodilution in Healthy Standing Horses. | LitMetric

Agreement of Bioreactance Cardiac Output Monitoring With Thermodilution in Healthy Standing Horses.

Front Vet Sci

Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA, United States.

Published: August 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Bioreactance is the continuous analysis of transthoracic voltage variation in response to an applied high frequency transthoracic current and was recently introduced for non-invasive cardiac output measurement (NICOM). We evaluated NICOM compared to thermodilution (TD) in adult horses. Six healthy horses were used for this prospective, blinded, experimental study. Cardiac output (CO) measurements were performed simultaneously using TD and the bioreactance method. Different cardiac output scenarios were established using xylazine (0.5 mg/kg IV) and dobutamine (1.5-3 mcg/kg/min). Statistical analysis was performed by calculating the concordance rate, performing a regression analysis, Pearson correlation, and Bland Altman. The TD-based CO and NICOM values were highly correlated for low, normal and high CO values with an overall correlation coefficient. A 4-quadrant plot showed an 89% rate of concordance. The linear regression calculated a relationship between NICOM and TDCO of Y = 0.4874 · X + 0.5936. For the corrected Bland Altman agreement, the mean bias and lower/upper limits of agreement were -0.26 and -3.88 to 3.41 L/min, respectively. Compared to TD, bioreactance- based NICOM showed good accuracy at induced low, normal, and high CO states in normal horses. Future studies performed under more clinical conditions will show if this monitor can help to assess hemodynamic status and guide therapy in horses in ICU settings and under general anesthesia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8369349PMC
http://dx.doi.org/10.3389/fvets.2021.701339DOI Listing

Publication Analysis

Top Keywords

cardiac output
16
bland altman
8
low normal
8
normal high
8
horses
5
nicom
5
agreement bioreactance
4
cardiac
4
bioreactance cardiac
4
output
4

Similar Publications