98%
921
2 minutes
20
Background: In this prospective, randomized, controlled observer-blinded study, we aimed to compare the efficacy of a single-operator technique called the Jedi Grip and a conventional technique requiring a double operator in ultrasound-guided axillary brachial plexus blocking.
Methods: Ninety-two patients (ASA I-II; aged 18-65 years old) who underwent elective hand, wrist and forearm surgery were randomly assigned to Group Conventional (C) or Group Jedi (J). In both groups, axillary plexus blockade was performed by applying 5 cc of a mixture of 10 cc of 0.5% bupivacaine and 10 cc of 2% prilocaine to the ulnar, radial, median, and musculocutaneous nerves. Parameters such as the performance time and number of needle passes were recorded during the procedure. Subsequently, a blinded observer evaluated and recorded parameters related to the blockade success. The main outcome variables were the performance time and success rate (surgical anesthesia).
Results: The block performance time of the Jedi technique was slightly longer than that of the conventional technique (220 (50), 202 (78) s, respectively) (median (IQR); p = 0.05). No significant difference was found between groups in terms of blocking success; 9 (20%) from the conventional group and 3 (6.4%) from the Jedi group were unsuccessful (p = 0.053). No differences were found in terms of arterial puncture, and no other complications occurred in either group. The motor-sensory block onset and termination times and initial analgesia requirements were similar.
Conclusion: The Jedi technique may be applied safely with similar block success and performance results as the conventional technique.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9373694 | PMC |
http://dx.doi.org/10.1016/j.bjane.2021.07.016 | DOI Listing |
Metab Brain Dis
September 2025
Department of Pharmacy, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277, Jiefang Avenue, Wuhan, Hubei, 430022, China.
Major depression disorder (MDD) is a mental condition that significantly threatens both physical and psychological health. This study aimed to discern variances in plasma metabolic profiles between MDD sufferers and healthy counterparts. Additionally, we tracked the hospitalization journey of MDD patients to investigate the normalization of metabolic irregularities through conventional treatment in the form of self-control.
View Article and Find Full Text PDFJ Synchrotron Radiat
November 2025
Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA.
Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on.
View Article and Find Full Text PDFNeurol Sci
September 2025
Pediatric Neurosurgery Unit, IRCCS Istituto Giannina Gaslini, Genoa, Italy.
Background: super-refractory status epilepticus (SRSE) is a rare and severe neurological condition associated with high mortality and significant long-term morbidity. In many cases, conventional medical treatments prove ineffective, with wide use of off-label therapies.
Methods: two researchers conducted a review of the medical records of subjects who had undergone VNS implantation in our tertiary Centre.
Eur Radiol Exp
September 2025
Department of Radio-diagnosis, Faculty of Human Medicine, Zagazig University, Zagazig, Egypt.
Background: Bone marrow (BM) lesion differentiation remains challenging, and quantitative magnetic resonance imaging (MRI) may enhance accuracy over conventional methods. We evaluated the diagnostic value and inter-reader reliability of Dixon-based signal drop (%drop) and fat fraction percentage (%fat) as adjuncts to existing protocols.
Materials And Methods: In this prospective two-center study, 172 patients with BM signal abnormalities underwent standardized 1.
Arch Orthop Trauma Surg
September 2025
Medical Faculty, University of Zurich (UZH), Zurich, Switzerland.
Background: Distal triceps tendon rupture is related to high complication rates with up to 25% failures. Elbow stiffness is another severe complication, as the traditional approach considers prolonged immobilization to ensure tendon healing. Recently, a dynamic tape was designed, implementing a silicone-infused core for braid shortening and preventing repair elongation during mobilization, thus maintaining constant tissue approximation.
View Article and Find Full Text PDF