A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Mid-term outcomes of rapid deployment aortic prostheses in patients with small aortic annulus. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: The Edwards Intuity valve is a rapid deployment aortic prosthesis that favours less invasive approaches. However, evidence about the clinical behaviour of their smaller sizes is scarce. Herein, we studied haemodynamic behaviours and clinical outcomes of small Intuity prostheses (19-21 mm) in comparison to larger Intuity prostheses (>21 mm).

Methods: This is an observational study including patients implanted with an Edwards Intuity rapid deployment aortic prosthesis. Patients with prosthesis sizes 19-21 and >21 mm were included. Baseline and perioperative variables, as well as adverse events during the follow-up were recorded and compared between groups.

Results: A total of 122 patients (37% female, mean age 75 ± 4.5 years) were included, of whom 54 (45%) were implanted with a small prosthesis and 68 (55%) with a prosthesis >21 mm. There were no significant differences between patients with small Intuity prostheses and patients with larger prostheses regarding in-hospital mortality (2% vs 4%, P = 0.43) or mortality during the follow-up (3.41 vs 2.45 per 100 patients-years; P = 0.58). Survival in the small Intuity valve group was 95% at 1 year and 83% at 6 years, whereas in the larger Intuity valve group was 96% at 1 year and 78% at 6 years. The presence of a small prosthesis did not influence mid-term survival (log-rank P-value = 0.62).

Conclusions: This study showed good clinical performance of Intuity aortic prostheses with appropriate mid-term survival in patients with the small aortic annulus. Thus, the Edwards Intuity rapid deployment aortic prosthesis may be considered as a potential option in patients with the small aortic annulus.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8923414PMC
http://dx.doi.org/10.1093/icvts/ivab175DOI Listing

Publication Analysis

Top Keywords

rapid deployment
16
deployment aortic
16
patients small
16
small aortic
12
aortic annulus
12
edwards intuity
12
intuity valve
12
aortic prosthesis
12
small intuity
12
intuity prostheses
12

Similar Publications