Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Medical practitioners need to understand the critical features of ECG beats to diagnose and identify cardiovascular conditions accurately. This would be greatly facilitated by identifying the significant features of frequency components in temporal ECG wave-forms using computational methods. In this study, we have proposed a novel ECG beat classifier based on a customized VGG16-based Convolution Neural Network (CNN) that uses the time-frequency representation of temporal ECG, and a method to identify the contribution of interpretable ECG frequencies when classifying based on the SHapley Additive exPlanations (SHAP) values. We applied our model to the MIT-BIH arrhythmia dataset to classify the ECG beats and to characterise of the beats frequencies. This model was evaluated with two advanced time-frequency analysis methods. Our results indicated that for 2-4 classes our proposed model achieves a classification accuracy of 100% and for 5 classes it achieves a classification accuracy of 99.90%. We have also tested the proposed model using premature ventricular contraction beats from the American Heart Association (AHA) database and normal beats from Lobachevsky University Electrocardiography database (LUDB) and obtained a classification accuracy of 99.91% for the 5-classes case. In addition, SHAP value increased the interpretability of the ECG frequency features. Thus, this model could be applicable to the automation of the cardiovascular diagnosis system and could be used by clinicians.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8155180 | PMC |
http://dx.doi.org/10.1007/s13534-021-00185-w | DOI Listing |