A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Continuous-wave near-infrared stimulated-emission depletion microscopy using downshifting lanthanide nanoparticles. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Stimulated-emission depletion (STED) microscopy has profoundly extended our horizons to the subcellular level. However, it remains challenging to perform hours-long, autofluorescence-free super-resolution imaging in near-infrared (NIR) optical windows under facile continuous-wave laser depletion at low power. Here we report downshifting lanthanide nanoparticles that enable background-suppressed STED imaging in all-NIR spectral bands (λ = 808 nm, λ = 1,064 nm and λ = 850-900 nm), with a lateral resolution of below 20 nm and zero photobleaching. With a quasi-four-level configuration and long-lived (τ > 100 μs) metastable states, these nanoparticles support near-unity (98.8%) luminescence suppression under 19 kW cm saturation intensity. The all-NIR regime enables high-contrast deep-tissue (~50 μm) imaging with approximately 70 nm spatial resolution. These lanthanide nanoprobes promise to expand the application realm of STED microscopy and pave the way towards high-resolution time-lapse investigations of cellular processes at superior spatial and temporal dimensions.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41565-021-00927-yDOI Listing

Publication Analysis

Top Keywords

stimulated-emission depletion
8
downshifting lanthanide
8
lanthanide nanoparticles
8
sted microscopy
8
continuous-wave near-infrared
4
near-infrared stimulated-emission
4
depletion microscopy
4
microscopy downshifting
4
nanoparticles stimulated-emission
4
depletion sted
4

Similar Publications