Objective: Quantitative Magnetic Resonance Imaging sequences have been investigated as objective imaging biomarkers of fibrosis and inflammation in Crohn's disease.

Aim: To determine the repeatability and inter- and intra-observer agreement of these measures in the prepared small bowel wall.

Methods: Ten healthy participants were scanned at 3 T on 2 separate occasions using T1 and T2 relaxometry, IVIM-DWI and MT sequences. Test-retest repeatability was assessed using the coefficient of variation (CoV) and intra-class correlation coefficients (ICCs) were used to evaluate the intra- and inter-observer agreement RESULTS: Test-retest repeatability in the bowel wall was excellent for apparent diffusion coefficient (ADC), magnetisation transfer ratio (MTR), T1, and diffusion coefficient D (CoV 5%, 7%, 8%, and 10%, respectively), good for perfusion fraction (PF) (CoV 20%) and acceptable for T2 (CoV 21%). Inter-observer agreement was good for the T2, D and ADC (ICC = 0.89, 0.86, 0.76, respectively) and moderate for T1 (ICC = 0.55). Intra-observer agreement was similar to inter-observer agreement.

Discussion: This study showed variable results between the different parameters measured. Test-retest repeatability was at least acceptable for all parameters except pseudo-diffusion coefficient D*. Good inter- and intra-observer agreement was obtained for T2, ADC and D, with these parameters performing best in this technical validation study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8578109PMC
http://dx.doi.org/10.1007/s10334-021-00931-2DOI Listing

Publication Analysis

Top Keywords

intra-observer agreement
12
test-retest repeatability
12
small bowel
8
bowel wall
8
healthy participants
8
inter- intra-observer
8
inter-observer agreement
8
diffusion coefficient
8
agreement
5
test-retest
4

Similar Publications

Objective: This study aims to systematically evaluate the inter- and intra-observer agreement regarding lesions with uncertain malignancy potential in Ga-68 PSMA PET/CT imaging of prostate cancer patients, utilizing the PSMA-RADS 2.0 classification system, and to emphasize the malignancy evidence associated with these lesions.

Methods: We retrospectively reviewed Ga-68 PSMA PET/CT images of patients diagnosed with prostate cancer via histopathology between December 2016 and November 2023.

View Article and Find Full Text PDF

Assessing the reproducibility of facebow transfers: A mesh-based intra-observer study.

J Prosthet Dent

September 2025

Assistant Professor, Department of Prosthetic Dentistry, UFR of Dental Sciences, Health College, University of Bordeaux, Bordeaux, France; and Researcher, University of Bordeaux, CNRS, Ministry of Culture, PACEA, UMR 5199, Pessac, France. Electronic address:

Statement Of Problem: The reproducibility of positioning the maxillary occlusal plane in an articulator with a facebow remains debated. Its clinical use is widespread, yet its reliability and clinical outcomes compared to other transfer methods under standardized conditions remain uncertain.

Purpose: The purpose of this in vitro study was to compare the intra-operator reproducibility of maxillary positioning on an articulator using a facebow compared to a standardized transfer table.

View Article and Find Full Text PDF

Isolated Congenital Middle Ear Malformations: Comparison of preoperative 0.1 mm Ultra-High-Resolution CT and Conventional High-Resolution CT.

AJNR Am J Neuroradiol

September 2025

From the Department of Otorhinolaryngology Head and Neck Surgery (J.G., Y.L., S.G.) and Department of Radiology (N.X., R.T., H.D.,Z.Y., Z.W., P.Z.), Beijing Friendship Hospital, Capital Medical University, Beijing, China.

Background And Purpose: Isolated congenital middle ear malformation contributes significantly to congenital hearing loss and growth problems. This study aims to compare 0.1 mm isotropic ultra-high-resolution computed tomography and conventional high-resolution computed tomography for assessing isolated congenital middle ear malformation, using surgical exploration as the gold standard.

View Article and Find Full Text PDF

Background: A significant contributory factor to the brachycephalic obstructive airway syndrome index of bulldogs is the diameter of their tracheas. Bulldogs are predisposed to tracheal hypoplasia. A non-invasive, financially reasonable and widely accessible screening test for tracheal diameter would be useful for assessing the most appropriate dogs to breed from within bulldog populations and may help in predicting results following upper airway surgery.

View Article and Find Full Text PDF

Background: Screw fixation is pivotal for prosthetic stability. For 3D-printed customized acetabular revision prostheses designed for complex, large-scale bone defects, precise adherence to preoperative screw trajectory planning is critical. However, there remains a lack of standardized three-dimensional (3D) evaluation protocols to quantify intraoperative screw angular alignment fidelity relative to preoperative digital plans, hindering universal validation criteria.

View Article and Find Full Text PDF