98%
921
2 minutes
20
Purpose: Minimally invasive surgery using short stems in total hip arthroplasty gained more popularity. The differences in change of hip offset and implant positioning in minimally invasive approaches are not fully known. Therefore, this study was conducted to evaluate the difference in reconstruction of hip offset and implant positioning in direct anterior approach (DAA) and minimally invasive anterolateral approach (AL MIS).
Methods: A single surgeon series of 117 hips (117 patients; mean age 65.54 years ± 11.47; index surgery 2014-2018) were included and allocated into two groups: group A (DAA) with 70 hips and Group B (AL MIS) with 47 patients operated. In both groups the same type of cementless curved short hip stem and press fit cup was used.
Results: Both groups showed an equal statistically significant increase of femoral (p < 0.001) and decrease of acetabular offset (p < 0.001). Between both groups no statistically significant difference in offset reconstruction, leg length difference or implant positioning could be found. Leg length increased in both groups significantly and leg length discrepancy showed no difference (group A: - 0.06 mm; group B: 1.11 mm; p < 0.001). A comparable number of cups were positioned outside the target zone regarding cup anteversion.
Conclusion: The usage of a curved short stem shows an equal reconstruction of femoro-acetabular offset, leg length and implant positioning in both MIS approaches. The results of this study show comparable results to the existing literature regarding change of offset and restoration of leg length. Malposition of the acetabular component regarding anteversion poses a risk.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8994713 | PMC |
http://dx.doi.org/10.1007/s00402-021-03977-y | DOI Listing |
Graefes Arch Clin Exp Ophthalmol
September 2025
Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College Hospital, No. 1 Shuaifuyuan Wangfujing Dongcheng District, China, 100730, Beijing.
Purpose: To evaluate the predictive value of the preoperative orientation and offset of angle alpha(chord alpha) and angle kappa(chord mu) for visual outcomes in patients who underwent trifocal intraocular lens (IOL) implantation.
Methods: Patient records of eyes that underwent AT LISA tri 839MP implantation were retrospectively collected and grouped according to the preoperative offset and orientations of chord alpha and chord mu. The two-dimensional location of each angle was described by the interaction of the orientation and offset.
Orthop Traumatol Surg Res
September 2025
Universitary Insitute of Locomotion and Sport, Pasteur II Hospital, Nice, France.
Background: This study aimed to evaluate how subscapularis tendon repair influences joint loads in relation to humeral offset and arm position.
Patients And Methods: Two fresh-frozen, whole-body cadaveric shoulders underwent a reverse total shoulder arthroplasty (rTSA) on the humeral side using an internal proprietary load-sensing system (LSS) (Goldilocks, Statera Medical, Montreal, Canada). In addition to three "complex" Activity Daily Life positions ("behind the back", "overhead reach", and "across the chest"), four standard postures (external rotation, extension, abduction, and flexion) were used to record the glenohumeral loads (Newtons) and their locations applied to the implant.
Front Public Health
September 2025
School of Business, Macau University of Science and Technology, Macao, Macao SAR, China.
Background: Diagnosis-related group (DRG) systems for healthcare reimbursement were recently introduced among hospitals in China, raising concerns about cost-shifting, where hospitals may increase charges for self-financing patients to offset reimbursement cuts by DRG. In 2018, both Nanchang and Ganzhou Cities in Jiangxi Province installed DRG information systems, but only Nanchang fully implemented the DRG system during the 2019-2020 pilot period.
Materials And Methods: Drawing from a healthcare administrative dataset of 14,310 patients' records, this study investigates the hospitalization costs associated with Intraocular Lens (IOL) implantation procedures in Jiangxi Province, China, from 2017 to 2020.
J Shoulder Elbow Surg
September 2025
Department of Orthopaedic Surgery, Konkuk University School of Medicine, Seoul, Korea. Electronic address:
Purpose: The aim of this study was to compare the accuracy of glenoid implant positioning achieved using emerging technologies, including patient-specific instrumentation (PSI), surgical navigation (NAV), and mixed reality (MR) in reverse total shoulder arthroplasty (rTSA).
Methods: A systematic literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, utilizing the PubMed, Scopus, and EMBASE databases to identify English-language original studies. Studies meeting predefined inclusion and exclusion criteria were selected to evaluate glenoid implant positioning in rTSA using PSI, NAV, and MR techniques.
Int Orthop
September 2025
Department of Orthopedic Surgery, Kangbuk Samsung Hospital, Seoul, Korea, Republic of.
Background: Multiple epiphyseal dysplasia (MED) is an inherited condition characterized by delayed and irregular ossification of the epiphyses that can lead to premature osteoarthritis. This study aimed to report the long-term outcomes of total hip arthroplasty (THA) in patients with MED.
Methods: We reviewed THAs performed in MED patients at a single institution between April 1997 and May 2014.