Publications by authors named "Rainer Hochgatterer"

: The present study investigates the five-year outcomes of hip arthroscopy for cam or pincer-type femoroacetabular impingement (FAI) and associated labral tears in a defined patient population. : Patients who underwent hip arthroscopy for cam or pincer-type arthroscopy femoroacetabular impingement (FAI) and labral tears at our hospital in the past five years were included. All patients who underwent revision-like a total hip arthroplasty (THA), a subsequent hip arthroscopy at another hospital, or had primary osseous diseases-were excluded.

View Article and Find Full Text PDF

Bioabsorbable and biodegradable implants offer new possibilities in orthopaedic and trauma surgery. As soon as the initial stability of the degradable implants has reached the qualities of conventional materials, new devices may find usage in younger and more demanding patients. Residual conventional osteosynthetic material or the necessity to remove metal increasingly seems to be more of an adverse event than daily practice in forefoot surgery.

View Article and Find Full Text PDF

This study shows a sufficient treatment with the Pavlik harness for all patients through all phases of developmental dysplasia of the hip (DDH) if there is a strict regime. : There was an ultrasound measurement stage of IIc or worse (D, IIIa/b, IVa/b) in 159 out of 7372 newborns between 1995 and 2006 (2.15%).

View Article and Find Full Text PDF

Purpose: Minimally invasive approaches (MIS) in total hip arthroplasty (THA) show inconsistent findings regarding planning adherence in digital templating. The purpose of this study is to evaluate any difference in planning adherence between the direct anterior approach (DAA) and an anterolateral MIS approach (AL MIS) in cementless short stem THA.

Methods: A single surgeon series of 222 THAs in 208 patients with an uncemented short curved stem and a bi-hemispherical acetabular cup were screened for inclusion.

View Article and Find Full Text PDF

Purpose: Short stems are increasingly used in total hip arthroplasty (THA) because of advantages in bone and soft tissue preservation and reconstruction of hip geometry. Digital templating is essential in determining the correct offset option and stem size in THA. However, the preoperative template sizes might be intraoperatively overruled.

View Article and Find Full Text PDF

Purpose: Short stems are increasingly used in in total hip arthroplasty (THA) because of advantages in bone and soft tissue preservation and reconstruction of hip geometry. Short stems can be inserted in a more varus position compared to conventional straight stems. This poses the risk of final varus misplacement of the femoral component, which is not intended in all femoral short stems.

View Article and Find Full Text PDF

Purpose: Obesity is associated with increased risk for surgical complications in total hip arthroplasty (THA). The impact of obesity on short-term complication in minimally invasive (MIS) anterolateral approach is not well known. Therefore, this study was conducted to evaluate the early complications within the first 90 days after THA using a MIS anterolateral approach with a short-curved stem stratified by Body Mass Index (BMI).

View Article and Find Full Text PDF

Purpose: Digital templating shows reliable accuracy for straight stem systems. In recent years, the implantation of short stems through minimally invasive approaches has gained more popularity. Minimally invasive approaches (MIS) show the risk of undersizing femoral components.

View Article and Find Full Text PDF

Purpose: Indications for unicompartmental knee arthroplasty (UKA) are controversial. Studies based solely on radiographic criteria suggest up to 49% of patients with knee osteoarthritis (OA) are suitable for UKA. In contrast, the 'Appropriate use criteria' (AUC), developed by the AAOS, apply clinical and radiographic criteria to guide surgical treatment of knee OA.

View Article and Find Full Text PDF

Purpose: Minimally invasive surgery using short stems in total hip arthroplasty gained more popularity. The differences in change of hip offset and implant positioning in minimally invasive approaches are not fully known. Therefore, this study was conducted to evaluate the difference in reconstruction of hip offset and implant positioning in direct anterior approach (DAA) and minimally invasive anterolateral approach (AL MIS).

View Article and Find Full Text PDF

Purpose: Minimally invasive (MIS) approaches in combination with short stems have gained popularity in recent years in total hip arthroplasty (THA). A decreased risk for periprosthetic femoral fractures (PFFs) is reported for cementless short-stem THA, but in contrast to other approaches, the risk factors for PFFs for short-stem THA using MIS anterolateral approach in supine position are not described in literature.

Methods: A single-center consecutive series of 1052 hips in 982 patients, performed between 2014 and 2019 with a short curved stem and a press fit using an MIS anterolateral approach in supine position, was retrospectively screened for inclusion.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate cardiorespiratory and hemodynamic responses during 24 h of continuous cycle ergometry in ultraendurance athletes.

Methods: Eight males (mean ± SD; age = 39 ± 8 yr, height = 179 ± 7 cm, body weight [Wt] = 77.1 ± 6.

View Article and Find Full Text PDF