Article Abstract

Exposure to a reduction in ambient pressure such as in high-altitude climbing, flying in aircrafts, and decompression from underwater diving results in circulating vascular gas bubbles (i.e., venous gas emboli [VGE]). Incidence and severity of VGE, in part, can objectively quantify decompression stress and risk of decompression sickness (DCS) which is typically mitigated by adherence to decompression schedules. However, dives conducted at altitude challenge recommendations for decompression schedules which are limited to exposures of 10,000 feet in the U.S. Navy Diving Manual (Rev. 7). Therefore, in an ancillary analysis within a larger study, we assessed the evolution of VGE for two hours post-dive using echocardiography following simulated altitude dives at 12,000 feet. Ten divers completed two dives to 66 fsw (equivalent to 110 fsw at sea level by the Cross correction method) for 30 minutes in a hyperbaric chamber. All dives were completed following a 60-minute exposure at 12,000 feet. Following the dive, the chamber was decompressed back to altitude for two hours. Echocardiograph measurements were performed every 20 minutes post-dive. Bubbles were counted and graded using the Germonpré and Eftedal and Brubakk method, respectively. No diver presented with symptoms of DCS following the dive or two hours post-dive at altitude. Despite inter- and intra-diver variability of VGE grade following the dives, the majority (11/20 dives) presented a peak VGE Grade 0, three VGE Grade 1, one VGE Grade 2, four VGE Grade 3, and one VGE Grade 4. Using the Cross correction method for a 66-fsw dive at 12,000 feet of altitude resulted in a relatively low decompression stress and no cases of DCS.

Download full-text PDF

Source
http://dx.doi.org/10.22462/03.04.2021.2DOI Listing

Publication Analysis

Top Keywords

vge grade
24
12000 feet
12
grade vge
12
venous gas
8
gas emboli
8
vge
8
decompression stress
8
decompression schedules
8
hours post-dive
8
cross correction
8

Similar Publications

Introduction: Venous gas emboli (VGE) are a common surrogate experimental endpoint for decompression sickness (DCS). VGE numbers are graded, and the peak post-dive grade is associated with the probability of DCS (PDCS). VGE are typically graded with the subject at rest when bubble numbers are stable, and again after limb flexions which elicit a transient shower of bubbles.

View Article and Find Full Text PDF

Eccentric upper-body exercise performed 24 h prior to high-altitude decompression has previously been shown to aggravate venous gas emboli (VGE) load. Yet, it is unclear whether increasing the muscle mass recruited (i.e.

View Article and Find Full Text PDF

Within-diver variability in venous gas emboli (VGE) following repeated dives.

Diving Hyperb Med

December 2023

Navy Experimental Diving Unit, Panama City, Florida, USA.

Introduction: Venous gas emboli (VGE) are widely used as a surrogate endpoint instead of decompression sickness (DCS) in studies of decompression procedures. Peak post-dive VGE grades vary widely following repeated identical dives but little is known about how much of the variability in VGE grades is proportioned between-diver and within-diver.

Methods: A retrospective analysis of 834 man-dives on six dive profiles with post-dive VGE measurements was conducted under controlled laboratory conditions.

View Article and Find Full Text PDF
Article Synopsis
  • A new decompression table called SWEN21 has been developed for the Swedish armed forces, aiming for a 1% risk level for decompression sickness (DCS) during dives.
  • In a study with 47 divers conducting 154 dives, venous gas emboli (VGE) were measured post-dive to assess DCS risk, revealing that peak VGE grades suggested a higher risk than expected.
  • The analysis indicated that the estimated DCS risk ranged from 4.7% to 11.1%, with three incidents of DCS occurring, all of which were treated successfully with hyperbaric oxygen.
View Article and Find Full Text PDF

Long-term alterations of pulmonary function (mainly decreased airway conductance and capacity of the lungs to diffuse carbon monoxide (DLCO)) have been described after hyperbaric exposures. However, whether these alterations convey a higher risk for divers' safety has never been investigated before. The purpose of the present pilot study was to assess whether decreased DLCO is associated with modifications of the physiological response to diving.

View Article and Find Full Text PDF