Factors Affecting Microbial Contamination on the Back Surface of Worn Soft Contact Lenses.

Optom Vis Sci

Faculty of Medicine and Health, School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.

Published: May 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Significance: The results of this study demonstrate that Smart Touch Technology packaging, which is designed to reduce and simplify contact lens handling before insertion, is effective in reducing the frequency of bacterial contamination of the back surface of contact lenses after short-term wear.

Purpose: The purpose of this study was to investigate the effect of lens packaging type, chelating agent, and finger contamination on microbial contamination on the back surface of worn soft contact lenses.

Methods: Twenty-five subjects completed each contralateral lens wear comparison in this randomized study: Smart Touch Technology versus conventional blister packaging for (1) silicone hydrogel lenses with ethylenediaminetetraacetic acid (EDTA) and (2) hydrogel lenses without EDTA in the packaging, and (3) silicone hydrogel lenses without EDTA versus hydrogel lenses with EDTA both in Smart Touch Technology packaging. Participants washed hands, underwent finger swabs, and inserted the lenses. After 45 minutes, lenses were removed aseptically and the posterior lens surfaces cultured.

Results: Thirty-eight subjects (average age, 30.9 ± 12.5 years) participated in this study. Overall, the level of back surface contamination was low for both lens materials, ranging from 0 to 43 colony-forming unit (CFU)/lens for the silicone hydrogel and 0 to 17 CFU/lens for the hydrogel lenses. The proportion of lenses with zero back surface contamination ranged from 16 to 64% for silicone hydrogel lenses and 28 to 64% for hydrogel lenses. Contact lenses from conventional packaging containing EDTA had 3.38 times increased risk (95% confidence interval [CI], 1.02 to 11.11; P = .05) of contamination being present compared with lenses from Smart Touch packaging with EDTA. Contact lenses from conventional packaging without EDTA had 3.4 times increased risk (95% CI, 1.02 to 11.36; P = .05) of contamination being present compared with Smart Touch packaging without EDTA, and silicone hydrogel lenses had a 6.28 times increased risk (95% CI, 1.65 to 23.81; P = .007) of contamination being present compared with hydrogels. The median (interquartile range) number of bacteria isolated from fingers used to perform lens insertion after handwashing but before lens insertion was not significantly different between the silicone hydrogel and hydrogel lenses (63.7 [204.2] vs. 59 [84.5], P = .09). Finger contamination was not significantly associated with lens contamination in the presence or absence of EDTA.

Conclusions: Smart Touch Technology packaging was effective in reducing the proportion of contaminated lenses. Although silicone hydrogel lenses were more likely to be contaminated, the presence of EDTA ameliorated this effect. Finger contamination was not associated with lens contamination.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8132605PMC
http://dx.doi.org/10.1097/OPX.0000000000001693DOI Listing

Publication Analysis

Top Keywords

hydrogel lenses
40
silicone hydrogel
28
smart touch
24
lenses
19
contact lenses
16
touch technology
16
packaging edta
16
contamination
13
contamination surface
12
technology packaging
12

Similar Publications

First Design of a Contact Lens for Diagnosis of Dehydration.

Biosensors (Basel)

August 2025

Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 655 W. Baltimore St, Baltimore, MD 21201, USA.

Dehydration is a serious medical problem for elderly patients and young children. The most widely used diagnostics are measurements of sodium ion (Na) and potassium ion (K) in blood serum. Dehydration is difficult to diagnose even by trained health care professionals because the body compensates to maintain the appearance of skin.

View Article and Find Full Text PDF

Purpose: To analyse the associations between ocular surface shape parameters and soft contact lens fitting.

Methods: A total of 106 eyes of 53 participants (53 right and 53 left eyes) fitted with standard silicone hydrogel soft lenses were analysed retrospectively. The sagittal height of the lenses was obtained from an independent publication.

View Article and Find Full Text PDF

Ink based graphene integration into commercial contact lenses.

Sci Rep

August 2025

Department of Mechanical and Nuclear Engineering, Material Science Center, Khalifa University of Science and Technology, P.O. Box 127788, Abu Dhabi, United Arab Emirates.

Introducing multiple functionalities to contact lenses (CLs) are achieved by additives such as nanomaterials, pigments, and dyes. CLs with graphene have been used in electromagnetic interference (EMI) shielding, drug delivery and sensing. Generally, CVD graphene or graphene nanocomposites are used during the manufacturing stage of CLs.

View Article and Find Full Text PDF

Pure zwitterionic hydrogels have attracted great interest in the biomedical field but are not widely used due to their weak mechanical properties. It has proven challenging to achieve an optimal balance between the antifouling ability and the mechanical properties of existing zwitterionic hydrogel enhancement methods. Consequently, pure zwitterionic hydrogel materials that exhibit high strength and resistance to fatigue were developed in this study.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the therapeutic efficacy, safety, and biocompatibility of calcium alginate hydrogel in suprachoroidal buckling procedures performed on rabbit eyes.

Methods: A total of 21 healthy New Zealand White rabbits underwent surgery, during which calcium alginate hydrogel was injected into the suprachoroidal space of one eye. Monthly ophthalmic examinations were performed for 3 months following the procedure.

View Article and Find Full Text PDF