Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: This study aimed to observe intraoperative changes in macular hole (MH) form using intraoperative optical coherence tomography (iOCT).
Methods: A total of 10 eyes from 10 patients with MH who underwent vitrectomy using iOCT from May 2015 to October 2015 at the Yamagata University Hospital were retrospectively evaluated. Accordingly, 25-gauge pars plana vitrectomy using iOCT with internal limiting membrane (ILM) peeling and sulfur hexafluoride gas tamponade was performed on each patient. During surgery, MHs were observed using iOCT over four points, namely, before posterior vitreous detachment (PVD) formation, after PVD formation, after ILM peeling, and after fluid-gas exchange. Thereafter, basal MH diameter and minimum aperture MH diameter were postoperatively analyzed.
Results: Before PVD formation, after PVD formation, after ILM peeling, and after fluid-gas exchange, the mean basal MH diameters were 690.7 ± 268.4, 683.3 ± 274.2, 683.7 ± 269.5, and 668.3 ± 261.4 μm, while the mean minimum aperture MH diameters were 278.3 ± 165.2, 283.0 ± 170.2, 257.0 ± 127.8, and 188.0 ± 105.0 μm, respectively. The mean minimum aperture MH diameter decreased significantly after fluid-gas exchange (one-way repeated measures ANOVA, p < 0.05). None of the patients exhibited intraoperative closure of the MHs. However, MH closure was confirmed in all patients after the surgery.
Conclusion: None of the patients demonstrated intraoperative MHs closure. Accordingly, the minimum aperture MH diameter was the first change formation to close after fluid-gas exchange.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8055364 | PMC |
http://dx.doi.org/10.2147/OPTO.S305927 | DOI Listing |