Article Abstract

The aim of this interdisciplinary work is a robust signal processing and autonomous machine learning framework to associate well-known (target) as well as any potentially unknown (non-target) peaks present within gas chromatography-mass spectrometry (GC/MS/MS) raw instrument signal. Particularly, this work evaluates three machine learning algorithms abilities to autonomously associate raw signal peaks based on accuracy in training and testing. A target is a known congener that is expected to be present within the raw instrument signal and a non-target is an unknown or unexpected compound. Autonomously identifying target peaks within the GC/MS/MS and associating them with non-target peaks can help improve the analysis of collected samples. Association of peaks refers to classifying peaks as known congeners regardless if the peak is a target or non-target. Uncertainty of peaks fitted and discovered through raw instrument signals from GC/MS/MS data is assessed to create topographical illustrations of target annotated peaks among sample raw instrument signals collected across diverse locations in the Chicago area. The term "annotated peak" is used to assign peaks found at specific retention times as a known congener. Adaptive signal processing techniques are utilized to smooth data and correct baseline drifts as well as detect and separate coeluted (overlapped) peaks in the raw instrument signal to provide key feature extraction. 150 air samples are analyzed for individual polychlorinated biphenyls (PCB) with GC/MS/MS across Chicago, IL. 80% of the data is used for training classification of target PCBs and 20% of the data is evaluated to identify and associate consistently occurring non-target peaks with target PCBs. A random forest classifier is used to associate identified peaks to target PCB peaks. Geographical topographical representations of target PCBs in the raw instrument signal demonstrates how PCBs accumulate and degrade in certain locations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8011560PMC
http://dx.doi.org/10.1109/access.2021.3056955DOI Listing

Publication Analysis

Top Keywords

raw instrument
24
instrument signal
16
peaks
13
machine learning
12
non-target peaks
12
target pcbs
12
target
9
signal processing
8
instrument signals
8
peaks target
8

Similar Publications

Significance: Melanoma's rising incidence demands automatable high-throughput approaches for early detection such as total body scanners, integrated with computer-aided diagnosis. High-quality input data is necessary to improve diagnostic accuracy and reliability.

Aim: This work aims to develop a high-resolution optical skin imaging module and the software for acquiring and processing raw image data into high-resolution dermoscopic images using a focus stacking approach.

View Article and Find Full Text PDF

Aims: Epilepsy affects more than 50 million peolple worldwide and requires reliable seizure detection systems to mitigate risks associated with unpredictable seizures. Existing machine learning frameworks are limited in generalizability, signal fidelity, and clinical translation, particularly when bridging invasive and non-invasive modalities. This study aims to develop a robust and generalizable seizure detection model capable of supporting cross-modal applicability.

View Article and Find Full Text PDF

DgeaHeatmap: an R package for transcriptomic analysis and heatmap generation.

Bioinform Adv

August 2025

Department of Anatomy and Cell Biology, Medical School OWL, Bielefeld University, Bielefeld 33615, Germany.

Motivation: The growing use of transcriptomic data from platforms like Nanostring GeoMx DSP demands accessible and flexible tools for differential gene expression analysis and heatmap generation. Current web-based tools often lack transparency, modifiability, and independence from external servers creating barriers for researchers seeking customizable workflows, as well as data privacy and security. Additionally, tools that can be utilized by individuals with minimal bioinformatics expertise provide an inclusive solution, empowering a broader range of users to analyze complex data effectively.

View Article and Find Full Text PDF

Purpose Prediction of the ectasia screening index, an estimator provided by the Casia2 instrument for identifying keratoconus, from raw optical coherence tomography data using convolutional neural networks. Methods Three convolutional neural networks models (ResNet18, DenseNet121 and EfficientNetB0) were employed to predict the ectasia screening index. Mean absolute error was used as the performance metric for predicting the ectasia screening index by the adapted convolutional neural network models on the test set.

View Article and Find Full Text PDF

This three-part study investigated alternative pre-processing techniques to better understand the differences in patterns of ground reaction force (GRF) and load rate (LR) among runners with running-related injury (RRI). 534 runners were assessed on an instrumented treadmill with 3D kinematic data capture. Participants were classified as "injured" or "uninjured" and "rearfoot" (RF) or "non-rearfoot" (non-RF) strikers.

View Article and Find Full Text PDF