A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Wall thickness-based adjustment of ablation index improves efficacy of pulmonary vein isolation in atrial fibrillation: Real-time assessment by intracardiac echocardiography. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Ablation index (AI) linearly correlates with lesion depth and may yield better therapeutic performance in pulmonary vein isolation (PVI) when tailored to a patient's wall thickness (WT) in the left atrium (LA).

Methods And Results: First study: In paroxysmal atrial fibrillation patients (PAF; n = 20), the average LA WT (mm) in each anatomical segment for PVI was measured by intracardiac echocardiography (ICE) placed in the LA; the optimal AI for creating 1-mm transmural lesion (AI/mm) was calculated. Second study: PAF (n = 80) patients were randomly assigned either to a force-time integral protocol (FTI; 400 g·s, n = 40) or a tailored-AI protocol (TAI; n = 40). In TAI, the LA WT in each segment was individually measured by ICE before starting ablation; a target AI was adjusted according to the individual WT in each segment (AI/mm × WT). The acute procedure outcomes and the 1-year AF-recurrence rate were compared between FTI and TAI. TAI had higher success rate of first-pass isolation (88% vs. 65%) and had lower incidence of residual PV-potentials/conduction-gaps after a circular ablation than FTI (15% vs. 45%). The procedure time to complete PVI decreased in TAI compared to FTI (52 vs. 83 min), being attributed to the increased radiofrequency power and the decreased radiofrequency application time in each point in TAI. TAI had a lower 1-year AF-recurrence rate than FTI.

Conclusion: TAI increased acute procedure success, decreased time for PVI, and reduced the 1-year AF-recurrence rate, compared to FTI. Understanding the precise ablation target and tailoring AI would improve the efficacy of PVI.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.15000DOI Listing

Publication Analysis

Top Keywords

1-year af-recurrence
12
af-recurrence rate
12
compared fti
12
pulmonary vein
8
vein isolation
8
atrial fibrillation
8
intracardiac echocardiography
8
tai
8
ablation target
8
acute procedure
8

Similar Publications