98%
921
2 minutes
20
A method for deriving the optical constants (/) of organic powdered materials using pressed pellets in the mid-infrared spectral range is introduced that combines variable angle spectroscopic ellipsometry and transmission spectroscopy. The approach is applied to anhydrous lactose, in which three different forms of pellets were pressed and measured: a pure lactose pellet and a mixed lactose/potassium bromide (KBr) pellet with a large analyte percentage were used for ellipsometric measurements, and a KBr transmission pellet with only a small analyte percentage was used for transmission measurements. The transmittance data provide an initial set of oscillators and improve the spectral fitting of weak absorption features (<0.01). Ellipsometric data for the pure and mixed pellets are then fit simultaneously to derive the final / values for lactose from 6000-400. An alternative method just using the ellipsometric data from the mixed pellet and the transmittance data is also presented and shows good agreement with the multi-sample analysis, providing a simpler method for powders that do not press easily into pure pellets. Finally, the derived optical constants were used to model the reflectance data, demonstrating a good match with the measured reflectance spectra if non-idealities are included.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.414107 | DOI Listing |
RSC Adv
September 2025
Laboratory of Spectroscopic Characterization and Optical Materials, Faculty of Sciences, University of Sfax B.P. 1171 3000 Sfax Tunisia
Lithium metavanadate (LiVO) is a material of growing interest due to its monoclinic 2/ structure, which supports efficient lithium-ion diffusion through one-dimensional channels. This study presents a detailed structural, electrical, and dielectric characterization of LiVO synthesized a solid-state reaction, employing X-ray diffraction (XRD), scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDS), and impedance/dielectric spectroscopy across a temperature range of 473-673 K and frequency range of 10 Hz to 1 MHz. XRD and Rietveld refinement confirmed high crystallinity and single-phase purity with lattice parameters = 10.
View Article and Find Full Text PDFJ Phys Chem B
September 2025
Department of Physics, Division of Nano and Biophysics, Chalmers University of Technology, Fysikgränd 3, Göteborg 41296, Sweden.
The detection of biological nanoparticles (NPs), such as viruses and extracellular vesicles (EVs), plays a critical role in medical diagnostics. However, these particles are optically faint, making microscopic detection in complex solutions challenging. Recent advancements have demonstrated that distinguishing between metallic and dielectric signals with twilight off-axis holographic microscopy makes it possible to differentiate between metal and biological NPs and to quantify complexes formed from metal and biological NPs binding together.
View Article and Find Full Text PDFInorg Chem
September 2025
Departmento de Química Inorgánica, Universidad de Valencia, C/Dr. Moliner 50, 46100 Burjasot, Valencia, Spain.
[Cu(3-bph)(PABA)(HO)] () (3-bph = ,'-bis(3-pyridylmethylene)hydrazine and PABA = -amino benzoate) is a pyridyl-N bridging Cu coordination polymer, and PABA acts as a carboxylate-O donor forming a square pyramidal CuNO motif following a zigzag one-dimensional (1D) lattice. The shows weak antiferromagnetic coupling ( = -0.196(1) cm), and emission appears at 352 nm (λ = 293 nm), which is selectively quenched by Fe via the FRET mechanism.
View Article and Find Full Text PDFTop Magn Reson Imaging
October 2025
BIOSPACE LAB, Nesles-la-Vallée, France.
Aims: Cardiac tumors are aggressive and asymptomatic in early stages, causing late diagnosis and locoregional metastasis. Currently, the standard of care uses gadolinium-based contrast agents for MRI, and the associated hypersensitivity reactions are a significant concern, such as gadolinium deposition disease. In addition, the proximity of cardiac lesions closer to vital structures complicates surgical interventions.
View Article and Find Full Text PDFJ Refract Surg
September 2025
From the Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany and.
Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.
Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH).