A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Study on Evaporation Characteristics of Water in Annular Liquid Pool at Low Pressures. | LitMetric

Study on Evaporation Characteristics of Water in Annular Liquid Pool at Low Pressures.

ACS Omega

Key Laboratory of Low-Grade Energy Utilization Technologies and Systems of Ministry of Education, School of Energy and Power Engineering, Chongqing University, Chongqing 400044, China.

Published: March 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In order to investigate the energy transfer mechanism and the nonequilibrium effect during water evaporation in its own pure vapor at low pressures, a series of precise measurements are conducted to obtain the temperature profile near the liquid-vapor interface and the evaporation rates in an annular pool in a closed chamber. The results show that the interface temperature of the vapor side is higher than that of the liquid side when water evaporates in its own pure vapor at low pressures (ranging from 394 to 1467 Pa), the temperature discontinuity across the interface exists in all experimental conditions. The magnitude of the temperature discontinuity is strongly affected by the vapor pressure. A uniform temperature layer with a thickness of about 2 mm is found below the evaporating interface because of the coupling effect of evaporation cooling and thermocapillary convection. The energy required for evaporation is mainly transferred by thermocapillary convection in the uniform temperature layer. Furthermore, the numerical simulation results confirm that the evaporation flux near the cylinders is much larger than that at the middle region, which implies that most of the latent heat required for evaporation is transferred to the interface near the cylinders.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7931419PMC
http://dx.doi.org/10.1021/acsomega.1c00134DOI Listing

Publication Analysis

Top Keywords

low pressures
12
pure vapor
8
vapor low
8
temperature discontinuity
8
uniform temperature
8
temperature layer
8
thermocapillary convection
8
required evaporation
8
evaporation transferred
8
evaporation
6

Similar Publications