Role of Robotic Surgery in Complex Revisional Bariatric Procedures.

Obes Surg

Division of General Surgery, Mayo Clinic, 4500 San Pablo Rd, Jacksonville, FL, 32224, USA.

Published: June 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Revisional bariatric surgery (RBS) is becoming more common, with an estimated increase of more than 300% from 2017 to 2018. For these complex procedures, the role of robotics is still debated. The purpose of our study is to report the safety and effectiveness of robotic-assisted RBSs.

Materials And Methods: A retrospective review of electronic medical records was conducted for robotic-assisted RBSs performed at the Mayo Clinic in Florida, between January 1, 2016, and January 1, 2020. Peri- and postoperative data were analyzed, reviewing patient characteristics, indications for surgery, and outcomes.

Results: From 160 RBSs performed during the study period, 67 were robotic-assisted and met inclusion criteria. Primary procedures included sleeve gastrectomy (26 [38.8%]), adjustable gastric band (24 [35.8%]), Roux-en-Y gastric bypass (14 [20.9%]), vertical-banded gastroplasty (2 [3.0%]), and duodenal switch (1 [1.5%]). RBSs performed were Roux-en-Y gastric bypass (49 [73.1%]), redo gastrojejunostomy (14 [20.9%]), and duodenal switch (4 [6.0%]). Rate of conversion to open procedure and rate of readmission 1 month after surgery were 6.0% and 7.5%, respectively. Rate of 30-day Clavien-Dindo grade III or higher adverse events was 4.5%. No anastomotic leaks were documented. Fifty-two patients presented with preoperative symptoms, and 69.2% reported improvement after RBS. Mean (SD) excess weight loss was 57.62% (23.80) 12 months after RBS.

Conclusion: Robotic-assisted RBSs are safe with low major adverse event rates. Symptom resolution and weight loss outcomes are acceptable.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11695-021-05272-6DOI Listing

Publication Analysis

Top Keywords

rbss performed
12
revisional bariatric
8
robotic-assisted rbss
8
roux-en-y gastric
8
gastric bypass
8
duodenal switch
8
weight loss
8
role robotic
4
surgery
4
robotic surgery
4

Similar Publications

Objective: To characterize coagulopathies before and after antivenom administration in rattlesnake-envenomated equids.

Methods: Client-owned envenomated equids treated with antivenom at Colorado State University (2023 to 2024). Rattlesnake bite severity score (RBSS), platelet count, prothrombin time, activated thromboplastin time, D-dimers, antithrombin, and viscoelastic testing variables were assessed before and after antivenom administration.

View Article and Find Full Text PDF

Blinded by occlusion: transforming painless vision loss assessment in the ED.

J Ultrasound

June 2025

Emergency Medicine Residency Program, UCF/HCA Florida Healthcare GME (Greater Orlando/Osceola), 700 W Oak St, Kissimmee, FL, 34741, USA.

Painless vision loss presents a diagnostic conundrum for Emergency Medicine physicians, encompassing a spectrum of differential diagnoses ranging from benign to potentially serious conditions. Among these, Central Retinal Artery Occlusion (CRAO) stands out as a critical diagnosis requiring prompt recognition and intervention. In the Emergency Department, identifying CRAO poses a unique challenge due to its reliance on a fundoscopic examination, a procedure that may not be routinely performed by emergency physicians.

View Article and Find Full Text PDF

The quantum cellular automata (QCA) paradigm offers an ultra-low-power approach for realizing nanocomputing circuits at the molecular level, offering high parallelism capabilities. This study introduces a coplanar and energy-efficient implementation of the approximate binary discrete cosine transform (BinDCT) module using QCA technology. The proposed BinDCT module integrates various sequential and combinatorial submodules, including multiplexers (MUXs), demultiplexers (DeMUXs), parallel-in-parallel-out right-shift registers (PIPO-RSRs), ripple carry adders (RCAs), and ripple borrow subtractors (RBSs).

View Article and Find Full Text PDF

This clinical trial aimed to evaluate and compare the retention and cariostatic effects of hydrophilic and hydrophobic resin-based sealants (RBSs) for sealing pits and fissures in the permanent molars of uncooperative children. A split-mouth and double-blind randomized clinical trial (RCT) was conducted among 6- to 9-year-old uncooperative children. One hundred and four sound mandibular and maxillary first permanent molars were randomly allocated to be sealed with group I (UltraSeal XT® hydro™) or group II (Helioseal-F) in 34 uncooperative children.

View Article and Find Full Text PDF

Purpose: A revisional bariatric surgery (RBS) is necessary in about 28% of the patients. The role of robotic surgery in RBS is still a subject of debate. We aim to report the outcomes of robotic-assisted RBS at our institution.

View Article and Find Full Text PDF