Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We report a simple, affordable (∼0.02 US $/test), rapid (within 5 min), and quantitative paper-based sensor integrated with smartphone application for on-spot detection of hemoglobin (Hgb) concentration using approximately 10 μL of finger-pricked blood. Quantitative analytical colorimetry is achieved via an Android-based application (Sens-Hb), integrating key operational steps of image acquisition, real-time analysis, and result dissemination. Further, feedback from the machine learning algorithm for adaptation of calibration data offers consistent dynamic improvement for precise predictions of the test results. Our study reveals a successful deployment of the extreme point-of-care test in rural settings where no infrastructural facilities for diagnostics are available. The Hgb test device is validated both in the controlled laboratory environment ( = 200) and on the field experiments ( = 142) executed in four different Indian villages. Validation results are well correlated with the pathological gold standard results ( = 0.9583) with high sensitivity and specificity for the healthy ( = 136) (>11 g/dL) (specificity: 97.2%), mildly anemic ( = 55) (<11 g/dL) (sensitivity: 87.5%, specificity: 100%), and severely anemic (n = 9) (<7 g/dL) (sensitivity: 100%, specificity: 100%) samples. Results from field trials reveal that only below 5% cases of the results are interpreted erroneously by classifying mildly anemic patients as healthy ones. On-field deployment has unveiled the test kit to be extremely user friendly that can be handled by minimally trained frontline workers for catering the needs of the underserved communities.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.0c02361DOI Listing

Publication Analysis

Top Keywords

extreme point-of-care
8
smartphone-enabled paper-based
4
paper-based hemoglobin
4
hemoglobin sensor
4
sensor extreme
4
point-of-care diagnostics
4
diagnostics report
4
report simple
4
simple affordable
4
affordable ∼002
4

Similar Publications

Plasmonic biosensor enabled by resonant quantum tunnelling.

Nat Photonics

June 2025

Institute of Bioengineering, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.

Metasurfaces provide an ideal platform for optical sensing because they produce strong light-field confinement and enhancement over extended regions that allow us to identify deep-subwavelength layers of organic and inorganic molecules. However, the requirement of using external light sources involves bulky equipment that hinders point-of-care applications. Here we introduce a plasmonic sensor with an embedded source of light provided by quantum tunnel junctions.

View Article and Find Full Text PDF

Unlabelled: We evaluated the correlation between the simplified and extended lung ultrasound (LUS) aeration scores with oxygenation in very preterm neonates during the first month of life, focusing on how the relationship varies over time and with gestational age (GA). This prospective observational study included neonates born before 32 weeks' GA. LUS was performed on postnatal days 2, 7, 14, and 28.

View Article and Find Full Text PDF

Objective: Bronchopulmonary dysplasia (BPD), the most frequent complication of extreme preterm birth, lacks not only of a comprehensive definition but also of effective treatments and predictive tools. Metabolomics is a valuable tool to unravel the underlying pathogenetic pathways of diseases and identify possible early markers. The objective of this study was to find metabolic signatures of subsequent BPD development, defined and stratified as per Jobe and Bancalari 2001 NHICD Consensus.

View Article and Find Full Text PDF

Background: Motivation for the study. In 2024, the World Health Organization modified the cut-off points that define anemia. The magnitude of the change in the prevalence of anemia in children aged 6-35 months in Peru, compared to the 2001 guideline, is unknown.

View Article and Find Full Text PDF

The total pool of blood's serum circulating L-amino acids (ΣAA) is an underused biomarker that integrates muscle protein turnover, nutritional status and metabolic disorders. Despite increasing clinical relevance, current methods for quantifying ΣAA, including colorimetry/fluorimetry and chromatography, are laboratory-bound, slow, and unsuitable for decentralized or extreme environments such as space missions. We report a self-contained, portable, calibration-free prototype device - Aminometer - for rapid quantitative analysis of ΣAA concentration in 7.

View Article and Find Full Text PDF