Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Non-urgent face-to-face outpatient ophthalmology appointments were suspended in the United Kingdom in March 2020, due to the COVID-19 outbreak. In common with other centres, Moorfields Eye Hospital NHS Foundation Trust (London) offered modified telephone consultations to new and follow-up patients in the low vision clinic. Here we assess the success of this telephone service.

Methods: Data were collected for 500 consecutive telephone low vision appointments. Successful completion of the assessment and clinical outcomes (low vision aids prescribed, onward referral) were recorded.

Results: Telephone assessments were completed for 364 people (72.8%). The most common reasons for non-completion were either no answer to the telephone call (75 people, 15%), or the patient declining assessment (20 people, 4%). There was no association between age and the likelihood of an assessment being completed. 131 new low vision aids were dispensed, 77 internal referrals were made and 15 people were referred to outside services. More than 80% of the low vision aids prescribed were useful.

Conclusions: Telephone low vision assessments were completed in about three-quarters of cases. About one-quarter of consultations resulted in new low vision aids being dispensed, which were generally found useful. Telephone low vision assessments can be used successfully in a large low vision clinic, but have many limitations when compared to face-to-face assessments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8014140PMC
http://dx.doi.org/10.1111/opo.12789DOI Listing

Publication Analysis

Top Keywords

low vision
44
vision aids
16
telephone low
12
vision
11
low
10
vision clinic
8
aids prescribed
8
assessments completed
8
aids dispensed
8
vision assessments
8

Similar Publications

Optically Controlled Memristor Enabling Synergistic Sensing-Memory-Computing for Neuromorphic Vision Systems.

Adv Mater

September 2025

Key Laboratory of Brain-Like Neuromorphic Devices and Systems of Hebei Province, College of Electronic and Information Engineering, Hebei University, Baoding, 071002, China.

Neuromorphic Visual Devices hold considerable promise for integration into neuromorphic vision systems that combine sensing, memory, and computing. This potential arises from their synergistic benefits in optical signal detection and neuro-inspired computational processes. However, current devices face challenges such as insufficient light/dark resistance ratios, mismatched transient photo-response, and volatile retention characteristics, limiting their adaptability to complex artificial vision systems.

View Article and Find Full Text PDF

Nanoparticle labels enable colorimetric point-of-care devices for rapid, low-cost diagnosis and health monitoring. Accurate interpretation of colorimetric assays relies on reliable perception of differences in quantitative color attributes such as hue, chromaticity, and saturation. This study examined interactions between physical factors such as nanoparticle shape, illumination, and sample environment, and biological factors affecting color vision deficit and optical signal processing that influenced perceived color difference.

View Article and Find Full Text PDF

Comprehensive Rehabilitation for Autosomal Dominant Retinitis Pigmentosa: A Case Report.

Case Rep Ophthalmol Med

September 2025

Department of Ophthalmology and Visual Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

A 62-year-old female with retinitis pigmentosa presented for a low vision rehabilitation evaluation. An updated spectacle prescription, filters, and task lighting were beneficial, but the patient was left with outstanding needs. She noted that she had lost her independence and felt trapped within her own home with nobody around who could fully understand her situation.

View Article and Find Full Text PDF

Background: Patients with clear cell renal cell carcinoma (ccRCC) often undergo organ resection, with treatment strategies based on recurrence risk. Current metastatic potential assessments rely on the WHO/ISUP grading system, which is subject to interobserver variability.

Methods: We developed an artificial intelligence (AI) model to classify cells according to contemporary grading rules and evaluated the prognostic significance of tumor cell profiles, particularly focusing on cells with prominent nucleoli.

View Article and Find Full Text PDF

Amorphous silicon resistors enable smaller pixels in photovoltaic retinal prosthesis.

J Neural Eng

September 2025

Hansen Experimental Physics Laboratory, Stanford University, 452 Lomita Mall, Stanford, California, 94305, UNITED STATES.

Clinical trials of the photovoltaic subretinal prosthesis PRIMA demonstrated feasibility of prosthetic central vision with resolution matching its 100 μm pixel width. To improve prosthetic acuity further, pixel size should be decreased. However, there are multiple challenges, one of which is related to accommodating a compact shunt resistor within each pixel that discharges the electrodes between stimulation pulses and helps increase the contrast of the electric field pattern.

View Article and Find Full Text PDF