Interdependencies between acoustic and high-speed videoendoscopy parameters.

PLoS One

Dep. of Otorhinolaryngology, Div. of Phoniatrics and Pediatric Audiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany.

Published: July 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In voice research, uncovering relations between the oscillating vocal folds, being the sound source of phonation, and the resulting perceived acoustic signal are of great interest. This is especially the case in the context of voice disorders, such as functional dysphonia (FD). We investigated 250 high-speed videoendoscopy (HSV) recordings with simultaneously recorded acoustic signals (124 healthy females, 60 FD females, 44 healthy males, 22 FD males). 35 glottal area waveform (GAW) parameters and 14 acoustic parameters were calculated for each recording. Linear and non-linear relations between GAW and acoustic parameters were investigated using Pearson correlation coefficients (PCC) and distance correlation coefficients (DCC). Further, norm values for parameters obtained from 250 ms long sustained phonation data (vowel /i/) were provided. 26 PCCs in females (5.3%) and 8 in males (1.6%) were found to be statistically significant (|corr.| ≥ 0.3). Only minor differences were found between PCCs and DCCs, indicating presence of weak non-linear dependencies between parameters. Fundamental frequency was involved in the majority of all relevant PCCs between GAW and acoustic parameters (19 in females and 7 in males). The most distinct difference between correlations in females and males was found for the parameter Period Variability Index. The study shows only weak relations between investigated acoustic and GAW-parameters. This indicates that the reduction of the complex 3D glottal dynamics to the 1D-GAW may erase laryngeal dynamic characteristics that are reflected within the acoustic signal. Hence, other GAW parameters, 2D-, 3D-laryngeal dynamics and vocal tract parameters should be further investigated towards potential correlations to the acoustic signal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7853476PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0246136PLOS

Publication Analysis

Top Keywords

acoustic signal
12
acoustic parameters
12
parameters
9
high-speed videoendoscopy
8
acoustic
8
gaw parameters
8
gaw acoustic
8
parameters investigated
8
correlation coefficients
8
females males
8

Similar Publications

Since its introduction more than 30 years ago, the blood oxygenation level-dependent (BOLD) contrast remains the most widely used method for functional MRI (fMRI) in humans and animal models. The BOLD contrast is typically acquired with echo planar imaging (EPI) to obtain sensitization of the signal during the echo time (TE) to dynamic changes in deoxyhemoglobin content, while achieving high spatiotemporal resolution and full brain coverage. However, EPI-based fMRI also faces multiple shortcomings, including sensitivity to body motion, susceptibility-related signal dropouts, interference with multimodal sensors, and loud acoustic noise.

View Article and Find Full Text PDF

Touch facilitates newborns' self-regulation: Systematic review of multidimensional arousal outcomes.

Neurosci Biobehav Rev

September 2025

Chair of Acoustics and Haptics, Centre for Tactile Internet with Human-in-the-Loop (CeTI), Technische Universität Dresden, Germany.

During the first month of life, exchanges between newborns and caregivers focus on helping babies regulate their physiological and behavioural states. Touch and bodily contact play a special role in facilitating arousal regulation and are often used to promote bonding, support at-risk babies, and manage pain. Here, we systematically review the extant evidence on the effects of touch interventions for newborns, specifically focusing on self-regulation and arousal as outcome measures.

View Article and Find Full Text PDF

Distortion products are tones produced through nonlinear effects of a system simultaneously detecting two or more frequencies. These combination tones are ubiquitous to vertebrate auditory systems and are generally regarded as byproducts of nonlinear signal amplification. It has previously been shown that several species of infectious-disease-carrying mosquitoes utilize these distortion products for detecting and locating potential mates.

View Article and Find Full Text PDF

[Lost in translation-an investigation of listening effort and performance in cochlear implant users in first and foreign language settings].

HNO

September 2025

Hörzentrum Düsseldorf, Klinik für Hals-Nasen-Ohrenheilkunde, Medizinische Fakultät und Universitätsklinikum Düsseldorf, Heinrich-Heine-Universität Düsseldorf, Moorenstr. 5, 40225, Düsseldorf, Deutschland.

Background And Objective: Speech comprehension in a foreign language under noise conditions presents an increased cognitive demand. For multilingual patients with cochlear implants (PwCI), this poses a particular challenge, as audiological routine diagnostics are typically conducted in the language of the clinical environment. This study investigates speech understanding in noise as well as the subjectively perceived listening effort in PwCI compared to normal-hearing (NH) individuals under both native and nonnative language conditions.

View Article and Find Full Text PDF

This study presents a non-destructive method for estimating surface acoustic wave attenuation, which is highly sensitive to microstructural features, especially at high frequencies. The method uses a single wideband dispersive interdigital transducer (IDT) that remotely emits acoustic waves at the sample's edge. Chirp compression of the temporal displacement response is achieved by correlating the excitation signal with the spatial configuration of the IDT's electrodes.

View Article and Find Full Text PDF