98%
921
2 minutes
20
Objectives: Contrast-enhanced ultrasound (CEUS) can provide quantitative perfusion metrics and may be useful to detect cerebral pathology in neonates and premature infants, particularly in extrauterine environments. The effect of hemodynamics on cerebral perfusion metrics is unknown, which limits the clinical application of this technology. We aimed to determine associations between systemic hemodynamics and concurrently measured brain perfusion parameters in an animal model of extrauterine support.
Methods: Nine fetal lambs were transferred to an extrauterine support device. Lumason® ultrasound contrast (0.1-0.3 ml) was administered via the umbilical vein and 90-second cine clips were obtained. Time-intensity-curves (TICs) were generated and time-dependent and area-under-curve (AUC) parameters were derived. Associations between brain perfusion metrics and hemodynamics including heart rate (HR) and mean arterial pressure (MAP) were evaluated by multilevel linear mixed-effects models.
Results: Eighty-six ultrasound examinations were performed and 72 examinations were quantifiable. Time-dependent measurements were independent of all hemodynamic parameters (all p ≥.05). Oxygen delivery and mean blood flow were correlated with AUC measurements (all p ≤.01). Physiologic HR and MAP were not correlated with any measurements (all p ≥.05).
Conclusion: Detected aberrations in time-dependent CEUS measurements are not correlated with hemodynamic parameters and are thought to reflect the changes in cerebral blood flow, thus providing a promising tool for evaluation of brain perfusion. CEUS brain perfusion parameters are not correlated with physiologic HR and MAP, but AUC-dependent measurements are correlated with oxygen delivery and blood flow, suggesting that CEUS offers additional value over standard monitoring. Overall, these findings enhance the applicability of this technology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jum.15642 | DOI Listing |
Retina
September 2025
Harvard Retinal Imaging Lab, Massachusetts Eye and Ear, Boston, MA, USA.
Purpose: To investigate associations among expanded field swept-source optical coherence tomography angiography (SS-OCTA) biomarkers and the development of tractional retinal detachment (TRD) in patients with proliferative diabetic retinopathy (PDR).
Methods: Patients with PDR without TRD at baseline were imaged with SS-OCTA. Quantitative and qualitative OCTA metrics were independently evaluated by two trained graders.
Front Physiol
August 2025
School of Mechanical Engineering and IEDT, Kyungpook National University, Daegu, Republic of Korea.
Introduction: Quantitative computed tomography (qCT) provides detailed spatial assessments of lung structure and function, while electrical impedance tomography (EIT) offers high temporal resolution for analyzing breathing patterns but lacks structural detail. This study investigates the correlation between qCT-based spatial variables and EIT-based temporal signals to elucidate the physiological relationships between these two modalities.
Methods: Six participants with asthma underwent pulmonary function tests (PFTs) before and after bronchodilator inhalation.
J Cardiovasc Magn Reson
September 2025
Royal Brompton and Harefield Hospitals, part of Guy's and St Thomas' NHS Foundation Trust, London, UK; National Heart and Lung Institute, Imperial College London, UK. Electronic address:
Background: Serial perfusion cardiovascular magnetic resonance (CMR) in symptomatic patients undergoing coronary artery bypass grafting (CABG) may provide mechanistic insight into dynamic abnormalities of the myocardium.
Objectives: To assess how changes in cardiac reperfusion and remodelling associate with symptom improvement in patients undergoing CABG METHODS: Patients awaiting elective CABG completed serial quality of life questionnaires and detailed CMR at baseline and at 6-12 months post CABG as per protocol. Automated fully quantitative stress and rest myocardial blood flow was calculated, alongside assessment of the visual ischaemic burden.
Radiol Imaging Cancer
September 2025
Department of Radiology, Breast Imaging Service, Memorial Sloan Kettering Cancer Center, New York, NY.
Purpose To evaluate intravoxel incoherent motion (IVIM) biomarkers across different MRI vendors and software programs for breast cancer characterization in a two-site study. Materials and Methods This institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study included 106 patients (with 18 benign and 88 malignant lesions) who underwent bilateral diffusion-weighted imaging (DWI) between February 2009 and March 2013. DWI was performed using 1.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Systems and Computer Engineering, Carleton University, Ottawa, ON, Canada.
Background: Lung lobe segmentation is required to assess lobar function with nuclear imaging before surgical interventions. We evaluated the performance of open-source deep learning-based lung lobe segmentation tools, compared to a similar nnU-Net model trained on a smaller but more representative clinical dataset.
Materials And Methods: We collated and semi-automatically segmented an internal dataset of 164 computed tomography scans and classified them for task difficulty as easy, moderate, or hard.