Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To implement a daily CBCT based dose accumulation technique in order to assess ideal robust optimization (RO) parameters for IMPT treatment of prostate cancer.

Methods: Ten prostate cancer patients previously treated with VMAT and having daily CBCT were included. First, RO-IMPT plans were created with ± 3 mm and ± 5 mm patient setup and ± 3% proton range uncertainties, respectively. Second, the planning CT (pCT) was deformably registered to the CBCT to create a synthetic CT (sCT). Both daily and weekly sampling strategies were employed to determine optimal dose accumulation frequency. Doses were recalculated on sCTs for both ± 3 mm/±3% and ± 5 mm/±3% uncertainties and were accumulated back to the pCT. Accumulated doses generated from ± 3 mm/±3% and ± 5 mm/±3% RO-IMPT plans were evaluated using the clinical dose volume constraints for CTV, bladder, and rectum.

Results: Daily accumulated dose based on both ± 3mm/±3% and ±5 mm/±3% uncertainties for RO-IMPT plans resulted in satisfactory CTV coverage (RO-IMPT CTV = 99.01 ± 0.87% vs. RO-IMPT CTV = 99.81 ± 0.2%, P = 0.002). However, the accumulated dose based on ± 3 mm/3% RO-IMPT plans consistently provided greater OAR sparing than ±5 mm/±3% RO-IMPT plans (RO-IMPT rectum = 2.93 ± 2.39% vs. RO-IMPT rectum = 4.38 ± 3%, P < 0.01; RO-IMPT bladder = 5.2 ± 7.12% vs. RO-IMPT bladder = 7.12 ± 9.59%, P < 0.01). The gamma analysis showed high dosimetric agreement between weekly and daily accumulated dose distributions.

Conclusions: This study demonstrated that for RO-IMPT optimization, ±3mm/±3% uncertainty is sufficient to create plans that meet desired CTV coverage while achieving superior sparing to OARs when compared with ± 5 mm/±3% uncertainty. Furthermore, weekly dose accumulation can accurately estimate the overall dose delivered to prostate cancer patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2020.11.035DOI Listing

Publication Analysis

Top Keywords

ro-impt plans
20
dose accumulation
12
ro-impt
9
treatment prostate
8
prostate cancer
8
daily cbct
8
accumulated dose
8
dose based
8
dose
6
plans
5

Similar Publications

We assessed the effect of beam size on plan robustness for intensity-modulated proton therapy (IMPT) of head and neck cancer (HNC) and compared the plan quality including robustness with that of intensity-modulated radiation therapy (IMRT). IMPT plans were generated for six HNC patients using six beam sizes (air-sigma 3-17 mm at isocenter for a 70-230 MeV) and two optimization methods for planning target volume-based non-robust optimization (NRO) and clinical target volume (CTV)-based robust optimization (RO). Worst-case dosimetric parameters and plan robustness for CTV and organs-at-risk (OARs) were assessed under different scenarios, assuming a ± 1-5 mm setup error and a ± 3% range error.

View Article and Find Full Text PDF

This retrospective treatment-planning study was conducted to determine whether intensity-modulated proton therapy with robust optimization (ro-IMPT) reduces the risk of acute hematologic toxicity (H-T) and acute and late gastrointestinal toxicity (GI-T) in postoperative whole pelvic radiotherapy for gynecologic malignancies when compared with three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated X-ray (IMXT) and single-field optimization proton beam (SFO-PBT) therapies. All plans were created for 13 gynecologic-malignancy patients. The prescribed dose was 45 GyE in 25 fractions for 95% planning target volume in 3D-CRT, IMXT and SFO-PBT plans and for 99% clinical target volume (CTV) in ro-IMPT plans.

View Article and Find Full Text PDF

Background: To assess the impact of systematic setup and range uncertainties for robustly optimized (RO) intensity modulated proton therapy (IMPT) and volumetric modulated arc therapy (VMAT) plans in patients with localized prostate cancer.

Methods: Twenty-six localized prostate patients previously treated with VMAT (CTV to PTV expansion of 3-5 mm) were re-planned with RO-IMPT with 3 mm and 5 mm geometrical uncertainties coupled with 3% range uncertainties. Robust evaluations (RE) accounting for the geometrical uncertainties of 3 and 5 mm were evaluated for the IMPT and VMAT plans.

View Article and Find Full Text PDF

Purpose: Anatomical changes and patient setup uncertainties during intensity modulated proton therapy (IMPT) of head and neck (HN) cancers demand frequent evaluation of delivered dose. This work investigated a cone-beam computed tomography (CBCT) and deformable image registration based therapy workflow to demonstrate the feasibility of proton dose calculation on synthetic computed tomography (sCT) for adaptive IMPT treatment of HN cancer.

Materials And Methods: Twenty-one patients with HN cancer were enrolled in this study, a retrospective institutional review board protocol.

View Article and Find Full Text PDF

Purpose: To implement a daily CBCT based dose accumulation technique in order to assess ideal robust optimization (RO) parameters for IMPT treatment of prostate cancer.

Methods: Ten prostate cancer patients previously treated with VMAT and having daily CBCT were included. First, RO-IMPT plans were created with ± 3 mm and ± 5 mm patient setup and ± 3% proton range uncertainties, respectively.

View Article and Find Full Text PDF