Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Automated segmentation of three-dimensional (3D) aortic magnetic resonance imaging (MRI) renders a possible retrospective selection of any location to perform quantification of aortic caliber perpendicular to its centerline and provides regional and global 3D biomarkers such as length, diameter, or volume. However, normative age-related values of such measures are still lacking. The aim of this study was to provide normal values for 3D aortic morphological measures and investigate their changes in aging and hypertension. This was a retrospective study, in which 119 healthy controls (HC: 48 ± 14 years, 61 men) and 82 hypertensive patients (HT: 60 ± 14 years, 43 men) were enrolled. 1.5 and 3 T/3D steady state free precession or spoiled gradient echo were used. Automated 3D aortic segmentation provided aortic length, diameter, volume for the ascending (AAo), and descending aorta (DAo), along with cross-sectional diameters at three aortic landmarks. Age, sex, body surface area (BSA), smoking, and blood pressures were recorded. Both groups were divided into two subgroups (≤50 years, >50 years). Statistical tests performed were linear regression for age-related normal values and confidence intervals, Wilcoxon rank sum test for differences between groups (HC or HT), and multivariate analysis to identify main determinants of aortic morphological changes. In HC, linear regression revealed an increase in the AAo (respectively DAo) length by 2.84 mm (7.78 mm), maximal diameter by 1.36 mm (1.29 mm), and volume by 4.28 ml (8.71 ml) per decade. AAo morphological measures were higher in HT patients than in HC both ≤50 years but did not reach statistical significance (length: +2 mm, p = 0.531; diameter: +1.4 mm, p = 0.2936; volume:+6.8 ml, p = 0.1857). However, length (+6 mm, p = 0.003), maximal diameter (+4 mm, p < 0.001) and volume (+12 ml, p < 0.001) were significantly higher in HT patients than in HC, both >50 years. In a multivariate analysis, age, sex, and BSA were the major determinants of aortic morphology, irrespective of the presence of hypertension. Global and segmental aortic length, volume, and diameters at specific landmarks were automatically measured from 3D MRI to serve as normative measures of 3D aortic morphology. Such indices increased significantly with age and hypertension among the elderly subjects. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 3.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.27502DOI Listing

Publication Analysis

Top Keywords

magnetic resonance
8
resonance imaging
8
aortic
8
three-dimensional aortic
8
aging hypertension
8
length diameter
8
diameter volume
8
normal values
8
aortic morphological
8
morphological measures
8

Similar Publications

The global rise in antibiotic resistance demands the urgent development of new antibacterial agents. This study investigated the antibacterial potential of four synthesized methoxy and thiophene chalcone derivatives (designated 3a, 4a, 3b, and 4b) against clinically relevant bacterial pathogens. These compounds were prepared through Claisen-Schmidt condensation, while their chemical structures were verified through applying Fourier-transform infrared, mass spectrometry, H nuclear magnetic resonance (NMR), and C NMR.

View Article and Find Full Text PDF

Background And Objectives: While reductions in optical coherence tomography (OCT) pRNFL and ganglion cell-inner plexiform layer thicknesses have been shown to be associated with brain atrophy in adult-onset MS (AOMS) cohorts, the relationship between OCT and brain MRI measures is less established in pediatric-onset MS (POMS). Our aim was to examine the associations of OCT measures with volumetric MRI in a cohort of patients with POMS to determine whether OCT measures reflect CNS neurodegeneration in this patient population, as is seen in AOMS cohorts.

Methods: This was a cross-sectional study with retrospective ascertainment of patients with POMS evaluated at a single center with expertise in POMS and neuro-ophthalmology.

View Article and Find Full Text PDF

Fetal 4D Flow CMR for Advanced Diagnostics of Congenital Heart Disease: A Prospective Cohort Study.

Eur Heart J Cardiovasc Imaging

September 2025

Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.

Aims: Fetal circulation undergoes complex changes in congenital heart disease (CHD) that are challenging to assess with fetal echocardiography. This study aimed to assess clinical feasibility and diagnostic value of 4D flow cardiac magnetic resonance (CMR) in fetal CHD.

Methods And Results: Pregnant women in advanced third trimester pregnancy with fetal CHD were prospectively recruited for fetal CMR between 08/2021 and 11/2024.

View Article and Find Full Text PDF

Soft tissue sarcomas are a heterogeneous group of malignancies arising from mesenchymal cells. Recent advancements in genomic profiling have identified novel gene fusions in these tumors, offering new insights into their pathogenesis and potential therapeutic targets. Here, we describe a spindle cell sarcoma harboring a novel gene fusion.

View Article and Find Full Text PDF

Ultrasmall MoC-MoO Heterojunction Coupled with Nitrogen-Doped Reduced Graphene for Boosting the Deep Oxidative Desulfurization of Fuel Oils.

Langmuir

September 2025

Engineering Technology Research Center of Preparation and Application of Industrial Ceramics of Anhui Province, Engineering Research Center of High-frequency Soft Magnetic Materials and Ceramic Powder Materials of Anhui Province, School of Chemistry and Material Engineering, Chaohu University, Chaoh

In this study, a MoC-MoO@NCrGO-900 composite catalyst comprising two-dimensional nitrogen-doped reduced graphene oxide (NCrGO) and ultrasmall molybdenum carbide-molybdenum dioxide (MoC-MoO) heterojunctions was synthesized. The optimized catalyst exhibited an outstanding oxidative desulfurization (ODS) performance. Specifically, a model oil containing 4000 ppm sulfur was completely desulfurized within 30 min, with a desulfurization efficiency of 98.

View Article and Find Full Text PDF