Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: Successful orthognathic surgery is fundamentally based on accurately carrying out the intended surgical plan intraoperatively. The purpose of this study was to evaluate the accuracy of bone-borne patient-specific maxillary cutting guides and 3-dimensional (3D)-printed plates in repositioning the maxilla during bimaxillary orthognathic surgery.
Materials And Methods: This was a retrospective case series consisting of patients who had undergone Le Fort I osteotomy with a patient-specific cutting guide and 3D-printed plate as well as a bilateral sagittal split osteotomy and had 6-week postoperative cone-beam computed tomography studies. The primary outcome variable was the difference between the position of the postoperative maxilla and the virtually planned maxilla measured at 10 landmarks in 3 dimensions. Other study variables included the preoperative diagnosis and planned surgical movement at each landmark. Descriptive statistics were tabulated, and bivariate analyses were performed.
Results: A total of 10 patients were included in this study. The mean age was 25.7 ± 8.1 years, and there were 5 female patients. The median planned surgical movement was 0.350 mm on the x-axis (right-left), 3.750 mm on the y-axis (anterior-posterior), and 1.704 mm on the z-axis (superior-inferior). The median absolute discrepancy between the postoperative position and the planned position on the x-axis, y-axis, and z-axis was 0.638, 0.798, and 0.481 mm, respectively. There was no significant difference in the discrepancies between the x-axis and y-axis (P = .575), x-axis and z-axis (P = .332), and y-axis and z-axis (P = .114).
Conclusions: Using a patient-specific cutting guide and 3D-printed plate when performing Le Fort I osteotomy allows for accurate 3-dimensional positioning of the maxilla in accordance with the surgical plan.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.joms.2020.11.031 | DOI Listing |