Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We proposed a differential fiber-optic SPR remote sensor with ultra-high sensitivity in telecom band. The working band of the sensor is designed as the C-band which is the low loss band of optical fiber communication aiming to improve the sensitivity and enable the capability of remote monitoring. The sensor head is a BK7 prism coated with Au/TiO films, enabling two channels for differential intensity interrogation. The intensities of the reflected lights through the channels vary oppositely within the measurement range of refractive index. Due to the sharp dip of angular resonant response in the C-band, the differential signal produces a steep slope as the refractive index of the sample varies, thus higher sensitivity is expected in a narrow measurement range. According to the results, the sensitivity is as high as 456 V/RIUs within the narrow measurement range of 1.3×10 RIUs and the resolution reaches to 6×10 RIUs. The measurement range can be tuned conveniently by adjusting the thickness of TiO film and can be expanded by increasing the number of sensing channels, which provides great convenience for the application of biosensor requiring high sensitivity.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.387413DOI Listing

Publication Analysis

Top Keywords

measurement range
16
differential fiber-optic
8
fiber-optic spr
8
telecom band
8
narrow measurement
8
sensitivity
5
highly sensitive
4
differential
4
sensitive differential
4
sensor
4

Similar Publications

Background: Cerebrovascular reactivity reflects changes in cerebral blood flow in response to an acute stimulus and is reflective of the brain's ability to match blood flow to demand. Functional MRI with a breath-hold task can be used to elicit this vasoactive response, but data validity hinges on subject compliance. Determining breath-hold compliance often requires external monitoring equipment.

View Article and Find Full Text PDF

Background: Despite considerable improvements in surgical treatment strategies for unstable ankle fractures, long-term follow-up studies on conventional treatment strategies are missing. The aim of the study was to assess the patient-reported long-term outcome (≥15 years) following surgically treated ankle fractures.

Methods: Retrospective, single-center, outcome study with a current follow-up.

View Article and Find Full Text PDF

Emergency department (ED) presentations are common for people in their last year of life, but the characteristics of these presentations by regional patients known to palliative care services are limited. To identify the characteristics and communication that occur when community-based palliative care (CBPC) patients present to the ED. A retrospective, cross-sectional study of CBPC presentations to the ED over 12 months.

View Article and Find Full Text PDF

Aims: The estimated glucose disposal rate (eGDR) is a simple, non-invasive measure of insulin resistance. In this exploratory analysis of FINEARTS-HF, we evaluated whether lower eGDR, reflecting greater insulin resistance, is associated with adverse outcomes in heart failure (HF).

Methods And Results: The eGDR was calculated at baseline using waist circumference, glycated haemoglobin, and hypertension status.

View Article and Find Full Text PDF

Aims: Skeletal muscle energetic augmentation might be a mechanism via which intravenous iron improves symptoms in heart failure, but no direct measurement of intrinsic mitochondrial function has been performed to support this notion. This molecular substudy of the FERRIC-HF II trial tested the hypothesis that ferric derisomaltose (FDI) would improve electron transport chain activity, given its high dependence on iron-sulfur clusters which facilitate electron transfer during oxidative phosphorylation.

Methods And Results: Vastus lateralis skeletal muscle biopsies were taken before and 2 weeks after randomization.

View Article and Find Full Text PDF