98%
921
2 minutes
20
Anesthesia with desflurane and remifentanil can be maintained with either fixed or titrated desflurane concentration. We hypothesized that the fixed-gas concentration (FG) method would reduce the number of anesthetic titrations without hypnotic and hemodynamic instability compared to the bispectral index (BIS)-guided (BG) method. Forty-eight patients were randomly allocated to the FG or BG groups. In the FG group, desflurane vaporizer setting was fixed at 1 age-corrected minimum alveolar concentration (MAC). In the BG group, desflurane was titrated to target a BIS level at 50. Remifentanil was titrated to maintain a systolic arterial pressure (SAP) of 120 mmHg in both groups. Our primary endpoint was the hypnotic stability measured by the wobble of BIS in performance analysis, and the secondary endpoints included the wobble of SAP, mean BIS value during surgery, and the number of anesthetic titrations. The BIS in the FG group showed significantly less wobble (3.9 ± 1.1% vs 5.5 ± 1.5%, P <0.001) but lower value (33 ± 6 vs 46 ± 7, P <0.001) than BG group. The wobble of SAP showed no difference between groups [median (inter-quartile range), 5.0 (4.1-7.5)% vs 5.2 (4.2-8.3)%, P = 0.557]. The numbers of anesthetic titrations in the FG group were significantly lower than the BG group (0 ± 0 vs 8 ± 5, P<0.001 for desflurane, 13 ± 13 vs 22 ± 17, P = 0.047 for remifentanil). Less wobble in BIS and reduced anesthetic titration without hemodynamic instability during the FG technique may be practical in balanced anesthesia using desflurane and remifentanil anesthesia. Clinical trial: This study was registered at ClinicalTrials.gov (NCT02283866).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7644031 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0241828 | PLOS |
PLoS One
January 2021
Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Anesthesia with desflurane and remifentanil can be maintained with either fixed or titrated desflurane concentration. We hypothesized that the fixed-gas concentration (FG) method would reduce the number of anesthetic titrations without hypnotic and hemodynamic instability compared to the bispectral index (BIS)-guided (BG) method. Forty-eight patients were randomly allocated to the FG or BG groups.
View Article and Find Full Text PDFEnviron Technol
April 2017
b Department of Chemistry and Chemical Engineering , Inha University, Incheon , Republic of Korea.
Removal kinetics for NO and SO by NaClO solution mist were investigated in a wet electrostatic precipitator. By varying the molar concentrations of NO, SO, and NaClO, the removal rates of NO and SO confirmed to range from 34.8 to 72.
View Article and Find Full Text PDFHuan Jing Ke Xue
November 2013
College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100, China.
Methyl mercaptan (CH3SH) is considered to be an important contributor to odors. It is a toxic, corrosive and acid gas. The absorption of CH3SH by alkaline solution is one of the most widely used processes, but the remained solution should be further treated.
View Article and Find Full Text PDFRev Sci Instrum
October 2011
Department of Applied Physics and Materials Research Center, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China.
Design of a system used for characterizing gas sensing materials is described. It is distinctive of being able to measure electrical and optical responses of a sample simultaneously, control a number of measurement parameters, perform fast exchange of gaseous environment, and be fully controlled automatically. These features make the system to be versatile in determining most concerned performance indexes of a gas sensing material (e.
View Article and Find Full Text PDFJ Colloid Interface Sci
May 2009
University College Dublin, School of Chemical and Bioprocess Engineering, Belfield, Dublin 4, Ireland.
Foamability, foam stability and the liquid volume of aqueous foams stabilized by dodecyltrimethylammonium bromide (C(12)TAB) are studied. The foams are generated with a sparging method at different gas flow rates and surfactant concentrations. It is found that at concentrations ccmc drainage dominates foam destruction while at c