A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The Clinical Impact of CLIR Tools toward Rapid Resolution of Post-Newborn Screening Confirmatory Testing for X-Linked Adrenoleukodystrophy in California. | LitMetric

The Clinical Impact of CLIR Tools toward Rapid Resolution of Post-Newborn Screening Confirmatory Testing for X-Linked Adrenoleukodystrophy in California.

Int J Neonatal Screen

Genetic Disease Screening Program, California Department of Public Health, Richmond, CA 94804, USA; (J.M.); (S.S.).

Published: September 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Since the start of X-linked adrenoleukodystrophy (ALD) newborn screening in California, more than half of the diagnosed cases were found to have an ATP binding cassette subfamily D member 1 () gene variant of uncertain significance (VUS). To determine retrospectively the likelihood that these were true positive cases, we used a web-based post-analytical tool in Collaborative Laboratory Integrated Reports (CLIR). Confirmatory plasma very long-chain fatty-acids (VLCFA) profiles for ALD screen positive infant boys were run through the CLIR ALD tool. We compared the distribution by variant classification (pathogenic, likely pathogenic, VUS, and no variant) with the CLIR tool score interpretation (non-informative, possibly ALD, likely ALD, and very likely ALD) and the current case diagnosis. The study showed that CLIR tool positive interpretations were consistent with 100% of the pathogenic and likely pathogenic variants on the gene if a more conservative guideline was used. The tool interpretations were also consistent with screened cases that were determined to not have disease (our no-disorder group). The CLIR tool identified 19 diagnosed ALD cases with VUS to be potential false positives, representing a 40% reduction among all diagnosed ALD cases with VUS. The reduction could be extended to 65% if a more aggressive threshold was used. Identifying such preventable false positives could alleviate the follow-up burden for patients, their families, and California Special Care Centers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7570356PMC
http://dx.doi.org/10.3390/ijns6030062DOI Listing

Publication Analysis

Top Keywords

clir tool
12
x-linked adrenoleukodystrophy
8
ald
8
pathogenic pathogenic
8
ald ald
8
interpretations consistent
8
diagnosed ald
8
ald cases
8
cases vus
8
false positives
8

Similar Publications