There are no clear guidelines on the compatibility between endoclips that remain in the gastrointestinal (GI) tract and magnetic resonance imaging (MRI). The purpose of this study was to investigate the effect of 3T (T) MRI on endoclips placed in excised pig tissues. Two types of endoclips were assessed: Olympus EZ (HX-610-135L) and QuickClip Pro (HZ-202LR). We assessed tissue damage or perforation and detachment of endoclips under 3T MRI magnetic field. We also evaluated the magnitude of force required to detach the endoclips from the porcine tissue. We measured the magnetic force acting on the Olympus EZ clips. QuickClip Pro clips were used as a control in this study. There was no tissue damage and no detachment of the endoclips (Olympus EZ and QuickClip Pro) during 3T MRI. The force required to detach the Olympus EZ clips ranged from 0.9 to 3.0 N. The translational magnetic force acting on the endoclips was 3.18 × 10 N. Ex vivo experiments showed that the magnetic field generated by 3 MRI did not cause tissue damage or perforation and did not detach the endoclips. Olympus EZ clips and QuickClip Pro clips in the GI tract appear to be safe during 3T MRI.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7539000 | PMC |
http://dx.doi.org/10.1038/s41598-020-73726-5 | DOI Listing |
Gastrointest Endosc
May 2024
Digestive Diseases Center, Showa University Koto Toyosu Hospital, Tokyo, Japan.
Background And Aims: Peroral endoscopic myotomy (POEM) is a safe and effective endoscopic treatment for achalasia and other esophageal motility disorders, and a versatile knife (TriangleTipKnife J [TTJ]; Olympus, Tokyo, Japan) is currently widely used in POEM. Recently, we reported a novel modification of TTJ, which was adjusted to a knife length of 2 mm by attaching a disposable clip (QuickClip Pro; Olympus) sheath to the tip as a hood attachment. This study compares the safety and effectiveness of TTJ and TTJ with a hood attachment (TTJ-H) in POEM.
View Article and Find Full Text PDFSci Rep
October 2020
Division of Gastroenterology, Department of Internal Medicine, National Health Insurance Service Ilsan Hospital, 100 Ilsan-ro Ilsan-donggu, Goyang-si, Goyang, 10444, Korea.
There are no clear guidelines on the compatibility between endoclips that remain in the gastrointestinal (GI) tract and magnetic resonance imaging (MRI). The purpose of this study was to investigate the effect of 3T (T) MRI on endoclips placed in excised pig tissues. Two types of endoclips were assessed: Olympus EZ (HX-610-135L) and QuickClip Pro (HZ-202LR).
View Article and Find Full Text PDFCase Rep Surg
December 2018
Department of General Surgery, Hospital Veris Delli Ponti, Scorrano, Italy.
Background: Bile leakage still remains a serious complication during cholecystectomies. In limited cases, this complication may occur from injury of the so-called ducts of Luschka. These rare ducts are usually discovered intraoperatively, and their presence poses the risk of bile injury and clinically significant bile leak.
View Article and Find Full Text PDF