Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We analyze the source of the position deviation and propose a demodulation recursive compensation algorithm to ensure a sub-millimeter resolution in improved optical frequency domain reflectometry. The position deviation between the geometric path and optical path changes with the temperature or strain, due to the elastic-optic and thermal-optic effects. It accumulates along the fiber and becomes large enough to affect the spectral correlation between the measured and reference spectra at the fiber end. The proposed algorithm compensates for the position deviation of each measuring point and aligns the measured spectra with its reference. The numerical and experimental results both reveal that the signal-to-noise ratio of the correlation is improved doubly and a sub-millimeter spatial resolution becomes available at a 30 m fiber end. The recursive compensation algorithm helps to restrain the correlation degeneration at the fiber end and promises an effective approach to a sub-millimeter resolution in optical frequency domain reflectometry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7583841PMC
http://dx.doi.org/10.3390/s20195540DOI Listing

Publication Analysis

Top Keywords

position deviation
16
recursive compensation
12
sub-millimeter resolution
12
compensation algorithm
8
optical frequency
8
frequency domain
8
domain reflectometry
8
numerical analysis
4
analysis recursive
4
position
4

Similar Publications

Background And Aim: The () gene plays a pivotal role in regulating growth, metabolism, and fat deposition in cattle. Genetic polymorphisms in this gene can influence phenotypic traits and may serve as molecular markers for selection in breeding programs. However, comprehensive characterization of gene variants in local Indonesian breeds, such as Madura cattle, remains limited.

View Article and Find Full Text PDF

Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.

View Article and Find Full Text PDF

BackgroundGlaucoma is recognized as the second-leading cause of complete blindness in developed countries and a significant contributor to irreversible vision loss worldwide. Understanding the potential genetic links between neurodegenerative diseases, such as Parkinson's disease, and glaucoma is crucial for developing preventive strategies.MethodsThis study utilized data from Genome-Wide Association Studies databases, focusing on European populations without gender restrictions.

View Article and Find Full Text PDF

Background: High-dose-rate (HDR) brachytherapy is essential in the treatment of locally advanced cervical cancer. While Iridium-192 (Ir-192) is commonly used, its short half-life imposes logistical and financial constraints, particularly in low- and middle-income countries (LMICs). Cobalt-60 (Co-60), with a longer half-life and lower operational costs, is a viable alternative.

View Article and Find Full Text PDF

Exploring the Arousal Intensity in Patients with Obstructive Sleep Apnea: Based on Odds Ratio Product.

Nat Sci Sleep

September 2025

Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, People's Republic of China.

Aim: Obstructive sleep apnea (OSA) is characterized by repetitive upper airway collapse during sleep, resulting in frequent cortical arousals. However, currently used frequency-based arousal metrics do not sufficiently capture the heterogeneity and clinical significance of arousal responses. The odds ratio product (ORP) is a novel electroencephalographic marker that provides a continuous assessment of sleep depth and has the potential to serve as an objective measure of arousal intensity.

View Article and Find Full Text PDF