Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) allows structure determination of membrane proteins and time-resolved crystallography. Common liquid sample delivery continuously jets the protein crystal suspension into the path of the XFEL, wasting a vast amount of sample due to the pulsed nature of all current XFEL sources. The European XFEL (EuXFEL) delivers femtosecond (fs) X-ray pulses in trains spaced 100 ms apart whereas pulses within trains are currently separated by 889 ns. Therefore, continuous sample delivery via fast jets wastes >99% of sample. Here, we introduce a microfluidic device delivering crystal laden droplets segmented with an immiscible oil reducing sample waste and demonstrate droplet injection at the EuXFEL compatible with high pressure liquid delivery of an SFX experiment. While achieving ~60% reduction in sample waste, we determine the structure of the enzyme 3-deoxy-D-manno-octulosonate-8-phosphate synthase from microcrystals delivered in droplets revealing distinct structural features not previously reported.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7481229PMC
http://dx.doi.org/10.1038/s41467-020-18156-7DOI Listing

Publication Analysis

Top Keywords

x-ray free
8
free electron
8
sample delivery
8
pulses trains
8
sample waste
8
sample
6
segmented flow
4
flow generator
4
generator serial
4
serial crystallography
4

Similar Publications

Objective: To compare 6- and 12-month results of femoral artery repair with xenopericardial and autologous venous patch in hybrid treatment of critical lower limb ischemia.

Material And Methods: A retrospective analysis included 60 patients with critical lower limb ischemia who underwent hybrid treatment (balloon angioplasty and stenting of iliac arteries and open reconstruction of femoral arteries). Patients were divided into 2 groups by 30 people depending on femoral artery repair (group 1 - autologous venous patch, group 2 - xenopericardial patch).

View Article and Find Full Text PDF

The calibration of the JET x-ray spectrometer is presented. The absolute throughput, diffractor focusing, and instrument function of the spectrometer are presented, and the quality of the ion temperature measurement is re-assessed, particularly at the lower end. The addition of a second diffractor enables the simultaneous measurements of the spectra from H- and He-like nickel, which widens the spatial coverage of the core-ion temperature measurements for high-performance plasmas at a fixed Bragg angle range.

View Article and Find Full Text PDF

Aims: Obesity is commonly hypothesized to lead to the development of heart failure (HF) in part due to increases in blood volume (BV) and left ventricular (LV) remodelling. Whether adiposity and obesity severity are associated with BV expansion and subsequent LV remodelling in middle-aged individuals at increased risk (IR) prior to the onset of HF is unknown.

Methods And Results: We analysed data from 96 middle-aged (40-64 years) non-obese (25.

View Article and Find Full Text PDF

Aims: Cardiac tumors are aggressive and asymptomatic in early stages, causing late diagnosis and locoregional metastasis. Currently, the standard of care uses gadolinium-based contrast agents for MRI, and the associated hypersensitivity reactions are a significant concern, such as gadolinium deposition disease. In addition, the proximity of cardiac lesions closer to vital structures complicates surgical interventions.

View Article and Find Full Text PDF

Background And Aims: We aimed to ascertain the prevalence of sarcopenia in patients with primary sclerosing cholangitis (PSC) and to assess the prognostic value as a biomarker for disease outcome.

Methods: We collected data from 224 patients (148 male, 76 female; mean age 41 years) from January 2002 to December 2021, with a confirmed diagnosis of PSC who underwent magnetic resonance imaging (MRI). Muscle mass was quantified at the level of the third lumbar vertebra by measurement of psoas muscle thickness (PMT) and total psoas muscle area (PMA).

View Article and Find Full Text PDF