98%
921
2 minutes
20
Key Points: Rod and cone photoreceptors convert light into electrochemical signals that are transferred to second order cells, initiating image-forming visual processing. Electroretinograms (ERGs) can detect the associated light-induced extracellular transretinal events, allowing for physiological assessment of cellular activity from morphologically intact retinas. We outline a method for economically configuring a traditional patch-clamp rig for performing high signal-to-noise ex vivo ERGs. We accomplish this by incorporating various 3D printed components and by modifying existing light pathways in a typical patch-clamp rig. This methodology provides an additional set of tools to labs interested in studying the physiological function of neuronal populations in isolated retinal tissue.
Abstract: Rod and cone photoreceptors of the retina are responsible for the initial stages in vision and convey sensory information regarding our visual world across a wide range of lighting conditions. These photoreceptors hyperpolarize in the presence of light and subsequently transmit signals to second-order bipolar and horizontal cells. The electrical components of these events are experimentally detectable, and in conjunction with pharmacological agents, can be further separated into their respective cellular contributions using electroretinograms (ERGs). Extracellular activity from populations of rods and cones generate the negative-going a-wave, while ON-bipolar cells generate positive-going b-waves. ERGs can be performed in vivo or alternatively using an ex vivo configuration, where retinas are isolated and transretinal photovoltages are recorded at high signal-to-noise ratios. However, most ERG set-ups require their own unique set of tools. We demonstrate how, at low cost, to reconfigure a typical patch-clamp rig for ERG recordings. The bulk of these modifications require implementation of various 3D printed components, which can alternatively aid in generating a stand-alone ERG set-up without a patch-rig. Further, we discuss how to configure an ERG system without a patch-clamp rig. Compared to in vivo ERGs, these are superior when measuring small responses, such as those that are cone-evoked or those from immature mouse retinae. This recording configuration provides high signal-to-noise detection of a-waves (300-600 µV) and b-waves (1-3 mV), and is ultimately capable of discerning small (1-2 µV) photovoltages from noise. These quick and economical modifications allow researchers to equip their technical arsenal with an interchangeable patch-clamp/ERG system.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9009099 | PMC |
http://dx.doi.org/10.1113/JP280014 | DOI Listing |
J Neurosci Methods
October 2024
Laboratory of General Physiology, Department of Biology and Biotechnology "L. Spallanzani", University of Pavia, Pavia 27100, Italy.
Background: The conventional "whole-cell patch-clamp" recording technique is widely used to measure the resting membrane potential (V) and to dissect the underlying membrane ionic conductances in isolated vascular endothelial cells.
New Method: Herein, we assessed whether the automated patch-clamp (APC) technology, which replaces the traditional patch-pipette with a planar substrate to permit researchers lacking formal training in electrophysiology to generate large amounts of data in a relatively short time, can be used to characterize the bioelectrical activity of vascular endothelial cells. We assessed whether the Port-a-Patch planar patch-clamp system, which is regarded as the smallest electrophysiological rig available on the market, can be used to measure the V and resting membrane currents in the human cerebrovascular endothelial cell line, hCMEC/D3.
PLoS One
August 2022
Sainsbury Wellcome Centre for Neural Circuits and Behaviour, University College London, London, United Kingdom.
This protocol is a practical guide for preparing acute coronal slices from the midbrain of young adult mice for electrophysiology experiments. It describes two different sets of solutions with their respective incubation strategies and two alternative procedures for brain extraction: decapitation under terminal isoflurane anaesthesia and intracardial perfusion with artificial cerebrospinal fluid under terminal isoflurane anaesthesia. Slices can be prepared from wild-type mice as well as from mice that have been genetically modified or transfected with viral constructs to label subsets of cells.
View Article and Find Full Text PDFMol Pharmacol
July 2021
George W Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia (R.E.P., M.C.Y., C.R.F.); Department of Pharmacology and Chemical Biology, Emory University School of Medicine, Atlanta, Georgia (R.E.P., A.J., S.F.T.); Department of Molecular Genetics & Microbiolo
Communication between neuronal cells, which is central to brain function, is performed by several classes of ligand-gated ionotropic receptors. The gold-standard technique for measuring rapid receptor response to agonist is manual patch-clamp electrophysiology, capable of the highest temporal resolution of any current electrophysiology technique. We report an automated high-precision patch-clamp system that substantially improves the throughput of these time-consuming pharmacological experiments.
View Article and Find Full Text PDFJ Physiol
November 2020
Department of Biology, The University of Akron, OH, USA.
Key Points: Rod and cone photoreceptors convert light into electrochemical signals that are transferred to second order cells, initiating image-forming visual processing. Electroretinograms (ERGs) can detect the associated light-induced extracellular transretinal events, allowing for physiological assessment of cellular activity from morphologically intact retinas. We outline a method for economically configuring a traditional patch-clamp rig for performing high signal-to-noise ex vivo ERGs.
View Article and Find Full Text PDFeNeuro
June 2018
Center for Learning and Memory and Department of Neuroscience, The University of Texas at Austin, Austin, TX 78712.
The dynamic clamp should be a standard part of every cellular electrophysiologist's toolbox. That it is not, even 25 years after its introduction, comes down to three issues: money, the disruption that adding dynamic clamp to an existing electrophysiology rig entails, and the technical prowess required of experimenters. These have been valid and limiting issues in the past, but no longer.
View Article and Find Full Text PDF