Article Abstract

Background: Since blood pressure tends to be unstable during induction of anesthesia in patients undergoing cardiovascular surgery, an artery catheter is often inserted before induction to continuously monitor arterial pressure during induction of anesthesia. ClearSight System™ enables noninvasive continuous measurement of beat-to-beat arterial pressure via a single finger cuff without pain using photoplethysmographic technology. If ClearSight System™ can replace intra-arterial pressure measurement, blood pressure could be easily and noninvasively assessed. However, the validity of ClearSight System™ during induction of anesthesia in patients undergoing cardiovascular surgery has not been evaluated. The aim of this study was to compare blood pressure measured by ClearSight System™ with intra-arterial pressure during induction of anesthesia for cardiovascular surgery.

Methods: This study was registered retrospectively. Data during induction of anesthesia for elective cardiovascular surgery were obtained for patients in whom noninvasive arterial pressure was measured by ClearSight System™ (APcs) and invasive radial arterial pressure (APrad) was measured simultaneously. According to the widely used criteria formulated by international standards from the Association for the Advancement of Medical Instrumentation, the acceptable bias and precision for arterial pressure measurements were fixed at < 5 mmHg and 8 mmHg, respectively.

Results: Data for 18 patients were analyzed. For 3068 analyzed paired measurements, values of APcs vs APrad bias (precision) were 13.2 (17.5), - 9.1 (7.3) and - 3.9 (7.8) mmHg for systolic, diastolic, and mean arterial pressures, respectively.

Conclusions: Mean arterial pressure measured by ClearSight System™ could be considered as an alternative for mean radial arterial pressure during induction of anesthesia for elective cardiovascular surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7370521PMC
http://dx.doi.org/10.1186/s12871-020-01091-xDOI Listing

Publication Analysis

Top Keywords

arterial pressure
24
clearsight system™
24
induction anesthesia
24
cardiovascular surgery
16
blood pressure
12
pressure
11
noninvasive continuous
8
pressure measurement
8
system™ induction
8
anesthesia cardiovascular
8

Similar Publications

Background: Tetrandrine (TET) demonstrates therapeutic potential for hypoxic pulmonary hypertension (HPH); however, its precise pharmacological mechanisms remain unclear. In this study, we aimed to investigate the effects of TET on pulmonary vascular remodeling (PVR) in HPH and elucidate the molecular pathways through which TET ameliorates HPH.

Methods: We established a rat model of HPH and evaluated the therapeutic effects of TET by measuring hemodynamic parameters, assessing right ventricular hypertrophy, and analyzing pathological changes in lung tissue.

View Article and Find Full Text PDF

Background: Pulmonary Hypertension (PH) is a significant contributor to cardiac mortality in Dilated Cardiomyopathy (DCM) patients. Inflammatory processes and oxidative stress play pivotal roles in the advancement of Pulmonary Hypertension (PH). The Monocyte-to-High-- Density-Lipoprotein Cholesterol Ratio (MHR), a newly identified biomarker indicative of inflammatory and oxidative stress, has not been extensively researched in the context of pulmonary hypertension, especially within the scope of dilated cardiomyopathy.

View Article and Find Full Text PDF

Aims: Acute restraint stress (RS) has been reported to activate the supraoptic nucleus of the hypothalamus (SON). The aim of the present study was to evaluate the role of glutamatergic neurotransmission in the SON on autonomic [mean arterial pressure (MAP), heart rate (HR), and tail cutaneous temperature], neuroendocrine (plasma levels of corticosterone, oxytocin, and vasopressin), and behavioral responses to RS.

Methods: Male Wistar rats with bilateral SON cannulas received microinjections of NMDA or non-NMDA receptor antagonists or vehicle before restraint stress, and the effects on cardiovascular, tail temperature, hormonal, and behavioral responses were evaluated RESULTS: Microinjection of DL-AP7 or NBQX into the SON reduced MAP increases and tail temperature decreases induced by RS.

View Article and Find Full Text PDF

Introduction: Pulmonary arterial hypertension (PAH) is a rare, progressive disease resulting from elevated pulmonary arterial pressure leading to right ventricular failure and death. Optimal adherence and persistence to medical therapy are necessary to improve outcomes. The objective of this study was to characterize adherence and persistence to first-line PAH therapies in patients newly initiating treatment.

View Article and Find Full Text PDF

Myocardial infarction (MI) is a leading cause of death worldwide and the most common precursor to heart failure, even after initial treatment. Precise evaluation of myocardial injury is crucial for assessing interventions and improving outcomes. Extensive evidence from both preclinical models and clinical studies demonstrates that the extent and severity of myocardial injury (i.

View Article and Find Full Text PDF