Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12928-020-00684-0DOI Listing

Publication Analysis

Top Keywords

late stent
4
stent thrombosis
4
thrombosis ostia
4
ostia bifurcation
4
bifurcation lesion
4
lesion correlation
4
correlation computed
4
computed tomographic
4
tomographic imaging
4
imaging histology
4

Similar Publications

Purpose: This study aims to evaluate the safety and efficacy of the CGuard dual-layer stent with its mesh embolic protection system (EPS) in elective cases for treatment of internal carotid artery stenosis and compares it to the Carotid Wallstent as benchmark.

Methods: In this retrospective, multicenter study, we analyzed data from consecutive patients who underwent carotid artery stenting with CGuard at two high-volume neurointerventional centers and compared them with prior consecutive patients treated with Carotid Wallstent (CWS), with and without a balloon guiding catheter (BGC) as protection, at the same institutions. Patient demographics, procedural details, clinical complications, early in-stent thrombosis and occlusion rates, and late follow-up restenosis rates were assessed.

View Article and Find Full Text PDF

Background: Repair strategies for pediatric vascular injuries must consider vascular growth and intervention durability. Endovascular interventions are increasingly utilized in pediatrics, particularly in unstable patients or for injuries in surgically morbid regions. This study describes a single-center experience with endovascular stenting in adolescent pediatric trauma.

View Article and Find Full Text PDF

First-generation drug-eluting stents (DES) with thick polymers may contribute to local vascular inflammation and late stent thrombosis. Thinner-strut DES, particularly those with biodegradable polymers and ultrathin struts, aim to reduce this risk by minimizing flow disturbance and vascular injury. Nonetheless, the long-term safety and efficacy of ultrathin biodegradable polymer sirolimus-eluting stents (BP-SES) compared to durable polymer everolimus-eluting stents (DP-EES) are still uncertain.

View Article and Find Full Text PDF

Aortoiliofemoral Lower Extremity CT Angiography.

Radiographics

October 2025

Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, CB 8131, St Louis, MO 63110.

CT angiography (CTA) of the aortoiliofemoral (AIF) arteries in the abdomen, pelvis, and lower extremities has become an invaluable tool in assessment of patients with peripheral arterial disease (PAD) and lower extremity trauma. AIF CTA provides rapid and comprehensive assessment of arterial inflow and outflow, guiding management of patients with chronic claudication and those with more acute manifestations, including atherothrombotic occlusion, embolic disease, or thrombosis of prior interventions such as bypass graft or stent placement. Careful attention to technique is critical in performing diagnostic AIF CTA, as pitfalls related to imaging too early or too late relative to the arrival of contrast material in the legs can lead to misdiagnosis or diagnostic uncertainty.

View Article and Find Full Text PDF

Background: Cumulative data has highlighted the efficacy of intra-vascular lithotripsy (IVL) in patients with stent failure (SF). However, it remains unclear whether the effectiveness of IVL, and subsequent clinical outcomes, are influenced by the timing of SF. We aimed to evaluate the outcomes of patients with SF undergoing IVL according to the age of index stent implantation.

View Article and Find Full Text PDF