Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The purpose of this study was to investigate the usage of an anatomical model to improve surgical planning of a complex schwannoma resection. As advancements in additive manufacturing continue to prosper, new applications of this valuable technology are being implemented in the medical field. One of the most recent applications has been in the development of patient-specific anatomical models for unique clinical education as well as for preoperative planning. In this case, a multidisciplinary team with expertise in research, three-dimensional printing, and medicine was formed to develop a three-dimensional printed model that could be used to help plan the reduction of a tumor from the cervical spine of a pediatric patient. Image segmentation and stereolithography creation were accomplished using Mimics and 3-matic, respectively. Models were developed on two different printer types to view different aspects of the region of interest. Reports from the operating surgeon indicated that the model was instrumental in the planning procedures of the operation and reducing operation time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7278293PMC
http://dx.doi.org/10.1177/2050313X20927600DOI Listing

Publication Analysis

Top Keywords

three-dimensional printed
8
anatomical model
8
pediatric patient
8
printed anatomical
4
model
4
model tumor
4
tumor management
4
management pediatric
4
patient purpose
4
purpose study
4

Similar Publications

Reconstructing bone defects remains a significant challenge in clinical practice, driving the urgent need for advanced artificial grafts that simultaneously promote vascularization and osteogenesis. Addressing the critical trade-off between achieving high porosity/strength and effective bioactivity at safe ion doses, we incorporated strontium (Sr) into β-tricalcium phosphate (β-TCP) scaffolds with a triply periodic minimal surface (TPMS) structure using digital light processing (DLP)-based three-dimensional (3D) printing. Systematically screening Sr concentrations (0-10 mol%), we identified 10 mol% as optimal, leveraging the synergy between the biomimetic TPMS architecture, providing exceptional mechanical strength (up to 1.

View Article and Find Full Text PDF

Urinary catheters: state of the art and future perspectives - a narrative review.

Mater Today Bio

October 2025

University of Maribor, Faculty of Medicine, Institute of Biomedical Sciences, Taborska Ulica 8, SI-2000, Maribor, Slovenia.

Catheter associated urinary tract infection (CAUTI) is the most frequent healthcare associated infection, arising from microbial adhesion to catheter surfaces, biofilm development, and the growing problem of antimicrobial resistance. Many publications have addressed CAUTI epidemiology, biofilm biology, or biomaterials for catheters in isolation, yet there is little literature that connects these areas into a coherent translational perspective. This review seeks to fill that gap by combining an overview of biofilm pathophysiology with recent advances in material based innovations for catheter design, including nanostructured and responsive coatings, sensor enabled systems, additive manufacturing, and three dimensional printing.

View Article and Find Full Text PDF

Fast and early detection of low-dose chemical toxicity is a critical unmet need in toxicology and human health, as conventional 2D culture models often fail to capture subtle cellular responses induced by sub-toxic exposures. Here, we present a bioengineered three-dimensional (3D) electrospun nanofibrous scaffold composed of polycaprolactone that enhances chromatin accessibility and primes fibroblasts for improved sensitivity to low-dose chemical stimuli in a short period. The scaffold mimics the extracellular matrix, providing topographical cues that reduce cytoskeletal tension and promote nuclear deformation, thereby increasing chromatin openness.

View Article and Find Full Text PDF

Introduction: anatomical deformities such as developmental dysplasia of the hip (DDH) and Perthes disease represent a challenge for reconstruction. The use of 3D-printed models can be helpful for assessing the deformity, bone mass, implant size, and orientation.

Objectives: to prospectively evaluate the outcomes of 3D simulation in primary total hip arthroplasty.

View Article and Find Full Text PDF

On-site mercury analyser employing enclosed quartz cell cold vapour atomic absorption spectrometry and 3D printing techniques.

Talanta

September 2025

Department of Chemistry and Biotechnology, Faculty of Science and Technology, Kochi University, 2-5-1 Akebono-cho, Kochi City, Kochi, 780-8520, Japan. Electronic address:

The development of on-site Hg analysers is crucial for the rapid evaluation of Hg concentrations in environmental research. However, the fabrication of Hg analysers requires simplification of analytical procedures and device miniaturisation. Based on the above requirements, our research group previously investigated enclosed quartz cell cold vapour atomic absorption spectrometry (EQC-CV-AAS) as a base technique for an on-site Hg analyser.

View Article and Find Full Text PDF